CDSCO License for Annuloplastyring
Medical Device Information
Intended Use
An annuloplasty ring implanted around the mitral or tricuspid heart valve for reconstructive treatment.

Comprehensive Guide to CDSCO Licensing for Annuloplasty Ring (Class C Medical Device)
As seasoned regulatory consultants with over 25 years of experience and having assisted 500+ companies in securing CDSCO approvals, we understand the complexities of medical device regulations in India. This guide focuses on the Annuloplasty ring—a Class C internal prosthetic replacement device used for reconstructive treatment of mitral or tricuspid heart valves—mapping out the detailed regulatory pathway, documentation, timelines, and cost considerations necessary to legally manufacture or import this device in India.
Understanding the Annuloplasty Ring and Its Regulatory Importance
An Annuloplasty ring is a critical cardiac implant designed to restore valve function by supporting and reshaping the mitral or tricuspid valve annulus. Given its invasive nature and direct contact with the cardiovascular system, the device is classified as Class C under CDSCO’s risk classification, indicating a moderate to high risk to patients.
Regulatory compliance ensures patient safety and device efficacy, making the CDSCO licensing process indispensable before launch or import in the Indian market. The device's notification under Notification No. 29/Misc/3/2017-DC (292) dated 06.06.2018 affirms its inclusion under CDSCO’s regulatory ambit.
CDSCO Regulatory Framework for Annuloplasty Ring
The regulatory framework for medical devices in India is governed by the Medical Device Rules, 2017 under the Drugs & Cosmetics Act, 1940. For Class C devices like the Annuloplasty ring, the Central Licensing Authority (CLA) under CDSCO handles manufacturing and import licenses.
Key regulatory steps include:
- Obtaining a Test License (Form MD13) for initial product testing
- Conducting product testing at CDSCO-approved laboratories
- Preparing exhaustive technical documentation
- Applying for Manufacturing License (Form MD7) or Import License (Form MD14/MD15)
- Undergoing CDSCO audits and inspections
- Resolving any departmental queries
Risk Classification and License Requirements for Annuloplasty Ring
The Annuloplasty ring falls under Class C (Moderate to High Risk) due to its internal prosthetic nature and critical clinical application. Hence, the mandatory license requirements are:
- Manufacturing License: MD9 License (Form MD7) granted by the Central Licensing Authority
- Import License: MD15 License (Form MD14/MD15) granted by the Central Licensing Authority
Class C devices require stringent testing, audit by CDSCO inspectors, and compliance with essential principles to ensure safety and performance.
Manufacturing License Process for Annuloplasty Ring (MD9)
The manufacturing license for Class C devices follows a multistep process:
Test License (Form MD13): Before full manufacturing license application, the manufacturer must obtain a test license for product testing. This typically takes 1.5 to 2 months.
Product Testing: Conduct mandatory product testing at CDSCO-approved labs. Refer to the Testing Laboratories list for approved facilities.
Technical Documentation: Prepare comprehensive documentation including Device Master File, Plant Master File, Essential Principles Checklist, Risk Management File, test reports, labels, and Instructions For Use (IFU).
License Application (Form MD7): Submit the manufacturing license application via the CDSCO MD Online Portal.
CDSCO Audit: CDSCO inspectors conduct a thorough audit of manufacturing premises and quality systems.
Query Resolution: Address any queries raised during the audit or application review.
License Grant: Upon satisfactory compliance, the MD9 manufacturing license is issued.
For a detailed walkthrough, refer to our MD9 License Guide.
Manufacturing License Documents Required
The documentation package is extensive and crucial for a successful application:
- Company Constitution and Incorporation Certificates
- Proof of ownership or lease of manufacturing premises
- Details and qualifications of technical staff
- Fire safety and Pollution NOCs
- Device Master File (DMF) detailing design, specifications, and manufacturing processes (Device Master File Guide)
- Plant Master File covering facility layout and equipment (Plant Master File Guide)
- Essential Principles Checklist indicating compliance with Indian standards
- Risk Management File demonstrating risk analysis and mitigation (Risk Management)
- Product Test Reports from CDSCO-approved labs
- Device labels and IFU
- Quality Management System Documents (preferably ISO 13485:2016 certification)
Having these documents meticulously prepared reduces back-and-forth with regulators and accelerates approval.
Import License Process for Annuloplasty Ring (MD15)
Importers of Class C devices must secure an MD15 license from CDSCO:
Document Preparation: Collate all necessary documents including existing manufacturing license from the country of origin, Free Sale Certificate, ISO certifications, CE certificate, and detailed device documentation.
License Application (Form MD14/MD15): Submit application through the CDSCO MD Online Portal. Note that test license is not required for import.
Query Resolution: Respond promptly to any departmental queries.
License Issuance: Upon satisfaction, CDSCO issues the import license.
For further guidance, see our Import License Guide.
Import License Documents Required
- Valid manufacturing license from the exporting country
- Free Sale Certificate from the country of origin
- ISO 13485:2016 certification
- CE Certificate or equivalent
- Device Master File and Plant Master File
- Wholesale drug license (if applicable)
- Company incorporation documents
Timeline and Processing Duration
- MD9 Manufacturing License: Approximately 4-5 months, including 1.5-2 months for test license issuance and product testing
- MD15 Import License: Approximately 5-6 months
Planning ahead and preparing documents thoroughly can significantly reduce delays.
Government Fees and Costs
- MD9 Manufacturing License: Rs. 50,000 per application + Rs. 1,000 per product
- MD15 Import License:
- Class C & D: Rs. 3,000 per site + Rs. 1,500 per product
Additional costs include product testing fees at government-approved laboratories and audit costs if engaging notified bodies.
Common Challenges and Practical Solutions
- Incomplete Documentation: Many applicants face delays due to missing or poorly prepared files. Utilize checklists and expert reviews.
- Delays in Test Reports: Coordinate closely with approved labs early to schedule testing and avoid bottlenecks.
- Audit Non-compliance: Ensure your manufacturing facility complies with Good Manufacturing Practices (GMP) and maintain updated Quality Management Systems.
- Query Handling: Respond promptly and comprehensively to CDSCO queries to avoid prolonged processing.
Expert Consultation and Support
With our extensive experience, we offer tailored support including document preparation, gap analysis, audit readiness, and liaison with CDSCO officials to expedite approvals. Leveraging expert advice can save significant time and cost.
Getting Started with Your CDSCO License Application for Annuloplasty Ring
Assess Your Device Classification: Confirm your Annuloplasty ring is Class C as per the Medical Device Classification.
Initiate Test License Application (If Manufacturing): Submit Form MD13 via the CDSCO MD Online Portal.
Engage CDSCO-approved Testing Laboratories: Schedule product testing early.
Prepare Comprehensive Documentation: Assemble DMF, PMF, risk files, and QMS documents.
Submit Manufacturing or Import License Application: Use Forms MD7 or MD14 accordingly.
Prepare for Audit and Queries: Conduct internal audits and prepare prompt responses.
Embarking on this structured approach will streamline your CDSCO licensing journey for the Annuloplasty ring, ensuring regulatory compliance and market access in India.
For personalized assistance or to start your application process, contact our regulatory experts today.