CDSCO License for Applicator for brachytherapy Cervical/endometrial remote after loading
Medical Device Information
Intended Use
A remote controlled brachytherapy applicator specifically designed for uterine cervical or intrauterine radiation therapy. It is designed to be temporarily implanted in the body. It serves as a guide for computer- controlled temporary placement and removal of a single or multiple therapeutic radiation sources in the uterine cervix and endometrium.

Expert Guidance on CDSCO Licensing for Applicator for Brachytherapy Cervical/Endometrial Remote After Loading
Navigating the regulatory landscape for medical devices in India can be complex, especially for specialized devices like the Applicator for Brachytherapy Cervical/Endometrial Remote After Loading. As a Class C radiotherapy device intended for temporary implantation in uterine cervical or intrauterine radiation therapy, it demands stringent compliance under the Central Drugs Standard Control Organization (CDSCO) framework. With over 25 years of regulatory experience and having assisted 500+ companies, we provide you with a detailed roadmap to secure your MD9 manufacturing license smoothly.
CDSCO Regulatory Framework for Radiotherapy Applicators
The CDSCO regulates medical devices under the Medical Device Rules 2017 and subsequent amendments. Devices are categorized based on risk class, with Class C devices like this brachytherapy applicator requiring a license from the Central Licensing Authority. The device’s intimate contact with internal tissues and its role in radiation therapy elevate its risk profile, mandating rigorous evaluation.
Risk Classification and License Requirements for Class C Devices
Your Applicator for Brachytherapy falls under Class C due to its invasive, therapeutic use involving ionizing radiation. This classification requires obtaining an MD9 manufacturing license, which is granted by the CDSCO Central Licensing Authority. The MD9 license process incorporates comprehensive product testing, quality system audits, and documentation review to ensure safety and efficacy.
Manufacturing License Process (MD9) for Class C Devices
The MD9 license application process for Class C devices includes several critical steps:
- Test License (Form MD13): Begin by applying for a test license, valid for 6 months, enabling you to conduct mandatory product testing. This phase typically takes 1.5 to 2 months.
- Product Testing: Tests must be performed in CDSCO-recognized laboratories. These include biocompatibility, sterility, and radiation safety assessments relevant to brachytherapy applicators. Refer to the list of testing laboratories approved by CDSCO.
- Document Preparation: Compile your Device Master File, Plant Master File, Risk Management File, Essential Principles Checklist, and Quality Management System (QMS) documents aligned with ISO 13485 standards.
- License Application Submission (Form MD7): Submit the application via the CDSCO MD Online Portal along with all supporting documents.
- Audit by CDSCO Inspectors: CDSCO conducts a rigorous audit of your manufacturing site and QMS compliance.
- Queries and Clarifications: Respond promptly to any queries from CDSCO to avoid delays.
- Grant of License (Form MD9): Upon successful review and audit, your MD9 license will be granted.
For a detailed walkthrough, our MD9 License Guide provides comprehensive insights.
Manufacturing License Documents Required
Prepare the following documentation meticulously:
- Company Constitution Documents: Certificate of Incorporation, Memorandum & Articles of Association.
- Proof of Premises Ownership or Lease Agreement: Establish manufacturing location legitimacy.
- Technical Staff Credentials: Qualification certificates for key personnel including Quality Manager and Technical Head.
- Fire NOC and Pollution Control NOC: Mandatory safety and environmental clearances.
- Device Master File (DMF): Detailed design, manufacturing process, and safety data. Our Device Master File guide can assist.
- Plant Master File (PMF): Manufacturing facility details and quality assurance processes. See our Plant Master File guide.
- Essential Principles Checklist: Declaration of conformity with Indian regulatory requirements.
- Risk Management File: Comprehensive risk analysis per ISO 14971. More at our Risk Management resource.
- Test Reports: From CDSCO-approved labs.
- Labels and Instructions for Use (IFU): Clearly indicating intended use and safety instructions.
- Quality Management System Documents: Evidence of ISO 13485 certification and internal procedures.
Import License Process (MD15) for Applicators
If you plan to import this device, the MD15 license is mandatory. The process is managed by the Central Licensing Authority and typically takes 5-6 months. Unlike manufacturing licenses, no test license is required, but extensive documentation must be submitted upfront.
Import License Documents Required
- Valid manufacturing license from the country of origin
- Free Sale Certificate
- ISO 13485:2016 certification
- CE Certificate or equivalent
- Device Master File and Plant Master File
- Wholesale License in India
- Company Constitution documents
Fees vary based on risk class, with Class C devices attracting approximately 1500 per product. Applications are submitted through the CDSCO MD Online Portal.
Timeline and Processing Duration
Step | Duration |
---|---|
Test License (MD13) | 1.5 to 2 months |
Product Testing | 1 to 1.5 months |
Document Preparation | Concurrent, 1 to 2 months |
License Application | Immediate upon docs ready |
CDSCO Audit | Scheduled within 1 month |
Query Resolution | 1 to 2 months |
Total Estimated Time | 4 to 5 months |
Planning for contingencies, such as audit scheduling and query clarifications, is crucial to avoid unexpected delays.
Government Fees and Costs
For your Class C device, expect the following fees:
- Application Fee: Rs 50,000 (non-refundable)
- Per Product Fee: Rs 1,000
- Testing Fees: Variable depending on the number and complexity of tests, typically ranging from Rs 1,00,000 to Rs 2,00,000
- Audit Fees: Usually included in application fees but may incur additional costs if external consultants are engaged
Budgeting for these expenses upfront enables smoother project management.
Common Challenges and Solutions
- Delayed Testing Results: Partner with CDSCO-recognized labs early to schedule tests promptly.
- Incomplete Documentation: Use a comprehensive checklist and expert review to ensure all files are complete.
- Audit Non-Compliance: Prepare for audits by conducting internal mock audits and training staff on regulatory expectations.
- Query Delays: Assign dedicated personnel for rapid response to CDSCO queries.
By anticipating these pain points, you can significantly reduce processing times.
Expert Consultation and Support
Navigating CDSCO licensing for specialized Class C devices like brachytherapy applicators requires in-depth knowledge of regulatory nuances. Our consultancy offers tailored support including:
- Documentation preparation and review
- Guidance on testing requirements
- Audit readiness and compliance coaching
- Liaison with CDSCO authorities
Our track record of successfully guiding 500+ companies through this process ensures you are in expert hands.
Getting Started with Your CDSCO License Application
- Assess Device Classification: Confirm your device as Class C using our Medical Device Classification resource.
- Engage Testing Laboratories: Schedule product testing with CDSCO-approved labs early.
- Prepare Required Documents: Leverage our guides to compile DMF, PMF, Risk Management File, and QMS documentation.
- Apply for Test License (Form MD13): Submit via the CDSCO MD Online Portal to commence testing phase.
- Plan for Audit: Ensure your manufacturing site and documentation are audit-ready.
- Submit MD9 License Application (Form MD7): After successful testing and audit preparation.
Starting early, maintaining organized documentation, and collaborating with experienced consultants can streamline your path to licensing success. For personalized assistance, feel free to reach out and leverage our expertise in CDSCO regulatory processes.
Embark on your journey to bring this critical radiotherapy device to the Indian market with confidence and compliance.