CDSCO License for Applicator for bronchial remote after loading brachytherapy
Medical Device Information
Intended Use
A remote controlled brachytherapy applicator specifically designed for bronchial radiation therapy. It is designed to be temporarily implanted in the body. It serves as a guide for computer-controlled temporary placement and removal of a single or multiple therapeutic radiation sources in the bronchus. This device group includes various applicators such as hollow needles, tubes, and catheters, as well as associated devices and connectors.

Comprehensive Guide to CDSCO Licensing for Applicator for Bronchial Remote After Loading Brachytherapy (Class C Medical Device)
Introduction: Understanding Your Device and Regulatory Importance
The Applicator for bronchial remote after loading brachytherapy is a critical class C radiotherapy medical device designed specifically for bronchial radiation therapy. This device facilitates the controlled placement and removal of therapeutic radiation sources within the bronchus, supporting highly precise cancer treatment. Given its temporary implantation and complex nature, regulatory compliance with the Central Drugs Standard Control Organization (CDSCO) is mandatory before marketing or manufacturing in India.
With over 25 years of expertise and having supported 500+ companies, we understand the nuances of securing CDSCO licenses for such advanced devices. Proper adherence to regulatory frameworks ensures not only legal compliance but also patient safety and market acceptance.
CDSCO Regulatory Framework for Radiotherapy Devices
CDSCO classifies medical devices into four risk classes: A, B, C, and D. The Applicator for bronchial remote after loading brachytherapy falls under Class C due to its invasive nature and critical therapeutic function.
Class C devices are regulated directly by the Central Licensing Authority (CLA). The applicable manufacturing license is the MD9 license, and import licensing requires the MD15 license. Both processes involve rigorous documentation, product testing, and audits to ensure compliance with the Medical Device Rules, 2017.
Risk Classification and License Requirements for Your Device
- Device Name: Applicator for bronchial remote after loading brachytherapy
- Risk Class: C (High risk, invasive, therapeutic)
- Regulatory License: MD9 Manufacturing License (for manufacturing in India), MD15 Import License (for imports)
- Regulatory Authority: Central Licensing Authority (CDSCO HQ, New Delhi)
Class C classification necessitates compliance with stringent quality management systems (ISO 13485:2016), thorough product testing, and detailed technical documentation.
Manufacturing License Process (MD9 License) for Class C Devices
The MD9 licensing process involves several key stages:
Test License Application (Form MD13): Before applying for MD9, manufacturers must secure a test license to conduct product testing. This typically takes 1.5 to 2 months.
Product Testing: Testing must be performed at CDSCO-approved laboratories to verify safety and performance. Refer to the list of testing laboratories authorized by CDSCO.
Document Preparation: Compile all required documents including technical, quality, and regulatory files.
Application Submission (Form MD7): Submit the MD9 license application via the CDSCO MD Online Portal.
Audit by CDSCO Inspectors: A detailed audit of manufacturing premises, quality systems, and documentation is conducted.
Queries Resolution: Respond promptly and comprehensively to any queries raised by the CDSCO or audit team.
License Grant (Form MD9): Upon successful completion, the license is issued granting permission to manufacture Class C devices.
The entire process generally spans 4 to 5 months from test license application to license grant.
Manufacturing License Documents Required for MD9
For the Applicator for bronchial remote after loading brachytherapy, the following documents are essential:
- Company Constitution: Certificate of incorporation, partnership deed, etc.
- Proof of Ownership or Tenancy of Manufacturing Premises
- Technical Staff Details: Qualifications and experience of key personnel
- Fire and Pollution NOC: Required to comply with local safety/environmental regulations
- Device Master File (DMF): Detailed device specifications, design, manufacturing process, and validation. Our Device Master File guide offers step-by-step instructions.
- Plant Master File (PMF): Manufacturing site details, infrastructure, and quality control processes. Learn more via our Plant Master File guide.
- Essential Principles Checklist: Demonstrating compliance with CDSCO Essential Principles of Safety and Performance
- Risk Management File: Comprehensive risk analysis and mitigation strategies aligned with ISO 14971. For implementation tips, see our Risk Management guide.
- Test Reports: From CDSCO-approved labs validating device safety and efficacy
- Labels and Instructions for Use (IFU): As per regulatory requirements
- Quality Management System (QMS) Documents: ISO 13485:2016 certification and related manuals
Import License Process (MD15 License) for Class C Devices
Manufacturers or importers intending to bring the Applicator for bronchial remote after loading brachytherapy into India must obtain an MD15 import license:
Document Preparation: Compile all relevant manufacturing and quality documents.
Application Submission (Form MD14): Submit the import license application through the CDSCO MD Online Portal.
Review and Queries: CDSCO evaluates documents and may issue queries.
License Grant (Form MD15): After satisfactory review, the import license is granted.
Unlike manufacturing licenses, no test license or onsite audits are required for import licenses.
Import License Documents Required for MD15
Key documents include:
- Valid Manufacturing License from the country of origin
- Free Sale Certificate proving the device is freely sold in the exporting country
- ISO 13485:2016 Certification
- CE Certificate or Equivalent
- Device Master File and Plant Master File
- Wholesale License (if applicable)
- Company Constitution Documents
Timeline and Processing Duration
Step | Duration |
---|---|
MD9 Test License (MD13) | 1.5 - 2 months |
Product Testing | 1 - 1.5 months (concurrent with test license or immediately after) |
MD9 License Application | 4 - 5 months total (including audit and query resolution) |
MD15 Import License | 5 - 6 months |
Government Fees and Costs
License Type | Application Fee | Per Product Fee |
---|---|---|
MD9 License | ₹50,000 | ₹1,000 |
MD15 Import License | Varies by class (Class C) ₹3,000/site | ₹1,500/product |
Please note these fees are exclusive of consultant fees, testing charges, and potential audit costs.
Common Challenges and Solutions
Challenge 1: Delays in Product Testing
- Solution: Engage early with CDSCO-approved labs and schedule testing promptly. Maintain clear communication to avoid bottlenecks.
Challenge 2: Incomplete Documentation
- Solution: Use comprehensive checklists and expert consultation to ensure all documents, especially DMF and PMF, meet CDSCO standards.
Challenge 3: Audit Non-Compliance
- Solution: Conduct internal audits and gap analysis before CDSCO inspection. Implement corrective actions proactively.
Challenge 4: Query Resolution Delays
- Solution: Assign a dedicated regulatory expert for timely and precise response to CDSCO queries.
Expert Consultation and Support
Navigating CDSCO regulations for Class C devices like the bronchial remote brachytherapy applicator can be intricate. Our seasoned regulatory consultants provide:
- Tailored gap analysis and documentation support
- Coordination with notified bodies and CDSCO officials
- Assistance with audit preparation and mock inspections
- End-to-end license application management
For detailed guidance, explore our MD9 License Guide.
Getting Started with Your CDSCO License Application
Register on the CDSCO MD Online Portal: Begin by creating your account at the CDSCO MD Online Portal.
Initiate Test License Application (MD13): Submit Form MD13 with preliminary documents to commence product testing.
Plan Testing and Documentation: Schedule product testing promptly with approved labs and prepare your Device Master File and Plant Master File concurrently.
Engage Regulatory Experts: Seek specialized consultancy early to streamline documentation and audit readiness.
Submit MD9 License Application (Form MD7): After successful testing, submit your complete application for manufacturing license.
Prepare for Audit: Conduct internal audits and arrange all documentation for CDSCO inspection.
Monitor and Respond to Queries: Maintain responsiveness throughout the CDSCO review process.
By following these actionable steps with expert support, manufacturers and importers can successfully obtain the CDSCO license for their bronchial remote after loading brachytherapy applicator, enabling safe and compliant market entry into India’s radiotherapy device sector.