CDSCO License for Applicator for pancreas manual brachytherapy
Medical Device Information
Intended Use
A manual brachytherapy applicator specifically designed for pancreatic radiation therapy. A single or module applicator designed to facilitate manual placement (puncture, endoscopic placement, or placement and removal using a diagnostic imaging system) of single or multiple therapeutic radiation sources in treatment sites in the pancreas. It may be designed to be standard in configuration or to handle specific radiation sources.

Comprehensive Guide to CDSCO Licensing for Applicator for Pancreas Manual Brachytherapy (Class C Device)
Navigating the regulatory landscape for a sophisticated medical device like the Applicator for Pancreas Manual Brachytherapy can be complex. With over 25 years of experience assisting 500+ companies in acquiring CDSCO licenses, we provide you with an expert, step-by-step guide tailored specifically for this Class C radiotherapy device. This guide covers regulatory frameworks, timelines, costs, documentation, and practical tips to ensure a smooth entry into the Indian market.
Understanding Your Device and Its Regulatory Importance
The Applicator for Pancreas Manual Brachytherapy is a high-precision medical device designed for manual placement of radioactive sources directly into pancreatic tissue to treat cancer through radiation. Given its critical role and potential risks associated with radiotherapy, the device is classified as Class C under CDSCO regulations, indicating a moderate to high risk.
Proper regulatory compliance ensures patient safety, product efficacy, and legal market access in India. A comprehensive license from the Central Licensing Authority is mandatory before manufacturing or importing this device.
CDSCO Regulatory Framework for Radiotherapy Devices
Medical devices in India fall under the purview of the Central Drugs Standard Control Organization (CDSCO). Radiotherapy devices such as your applicator are regulated stringently due to their involvement with ionizing radiation.
The regulatory pathway involves obtaining the appropriate license based on risk classification, which for your device is Class C. This requires a manufacturing license under Form MD9 if you manufacture in India or an import license under Form MD15 if you plan to import.
Risk Classification and License Requirements
- Device Risk Class: C (Moderate to High Risk)
- License Type: MD9 Manufacturing License (if manufacturing in India)
- Authority: Central Licensing Authority (CDSCO Headquarters)
For Class C devices, CDSCO mandates a rigorous evaluation including test license issuance, product testing at government-approved laboratories, quality audits, and detailed documentation.
Learn more about medical device classification.
Manufacturing License Process (MD9) for Class C Devices
The MD9 license process typically spans 4 to 5 months and involves the following key steps:
Test License Application (Form MD13): You must first apply for a test license which generally takes 1.5 to 2 months to be granted. This allows manufacturing of the device samples for testing.
Product Testing: Conduct mandatory product testing at CDSCO-approved laboratories. The list of approved testing labs can be consulted for identifying appropriate facilities.
Documentation Preparation: Prepare and compile comprehensive technical files including Device Master File, Plant Master File, Risk Management File, Essential Principles Checklist, and Quality Management System (QMS) documentation.
Application Submission (Form MD7): Submit your manufacturing license application for MD9 through the CDSCO MD Online Portal.
CDSCO Audit: An audit will be conducted by CDSCO inspectors to verify compliance with Good Manufacturing Practices (GMP) and other regulatory requirements.
Query Resolution: Address any queries or observations raised by the CDSCO or auditors promptly.
License Grant: Upon successful completion of all steps, the MD9 manufacturing license is granted.
For detailed guidance on MD9 license application, refer to our MD9 License Guide.
Manufacturing License Documents Required for Your Device
To apply for the MD9 license, the following documents are essential:
- Company Constitution (Incorporation Certificate, Memorandum & Articles of Association)
- Proof of Ownership or Lease Agreement of Manufacturing Premises
- Details and Qualifications of Technical Staff
- Fire NOC and Pollution Control Board NOC
- Device Master File (DMF): Detailed specifications, design, manufacturing processes. See our Device Master File guide for preparation tips.
- Plant Master File (PMF): Details of manufacturing facilities and quality controls. Learn how to create an effective PMF here.
- Essential Principles Checklist showing compliance with Indian Medical Device Rules
- Risk Management File demonstrating thorough hazard analysis and mitigation strategies. For practical advice, visit our Risk Management guide.
- Test Reports from CDSCO-approved labs
- Product Labels and Instructions for Use (IFU)
- Quality Management System documents (ISO 13485:2016 certification recommended)
Import License Process (MD15) for Class C Devices
If you plan to import the Applicator for Pancreas Manual Brachytherapy, the import license (Form MD15) must be obtained from CDSCO’s Central Licensing Authority. The process generally takes 5 to 6 months and includes:
Document preparation including Manufacturing License from the country of origin, Free Sale Certificate, ISO 13485:2016 certification, CE Certificate, Device Master File, Plant Master File, Wholesale License, and Company Constitution.
Application submission through the CDSCO MD Online Portal.
Review and query resolution by CDSCO officials.
Grant of MD15 import license.
Refer to our detailed Import License Guide for comprehensive support.
Timeline and Processing Duration
Process Step | Duration Estimate |
---|---|
Test License (MD13) | 1.5 to 2 months |
Product Testing | 1 to 1.5 months |
Documentation Preparation | Concurrent or 1 month |
Application Review & Audit | 1.5 to 2 months |
Query Resolution | 0.5 to 1 month |
Total for MD9 License | 4 to 5 months |
Government Fees and Costs
- Application Fee: Rs 50,000 per MD9 license application
- Per Product Fee: Rs 1,000 per product included in the license
- Additional costs include product testing fees (varies by lab), audit charges (if applicable), and consultancy fees if you engage expert support.
Common Challenges and Practical Solutions
Documentation Gaps: Missing or incomplete Device Master or Plant Master Files cause delays. We recommend early preparation and cross-checking with CDSCO requirements.
Testing Delays: Choosing the right CDSCO-approved testing lab upfront helps avoid bottlenecks.
Audit Non-Compliance: Ensure your manufacturing and quality systems are audited internally before CDSCO visits.
Query Resolution: Respond to CDSCO queries promptly with clear, evidence-backed explanations to expedite approval.
Our experience shows proactive planning and engaging expert consultants significantly smoothens the licensing journey.
Expert Consultation and Support
With our 25+ years in the industry and hands-on experience with over 500 successful CDSCO licensing projects, we provide:
- Tailored regulatory strategy and submission planning
- Document preparation and gap analysis
- Coordination with notified bodies and testing labs
- Mock audits and training to ensure compliance
- Ongoing liaison with CDSCO for faster query resolution
Partnering with experts reduces your risk of rejection and accelerates time-to-market.
Getting Started with Your CDSCO License Application for the Applicator for Pancreas Manual Brachytherapy
Confirm Device Classification: Verify your device is Class C using the official CDSCO classification guidelines.
Initiate Test License Application: Prepare and submit Form MD13 via the CDSCO MD Online Portal.
Select Approved Testing Laboratory: Reach out to labs from the CDSCO testing labs list and schedule required tests.
Prepare Complete Documentation: Assemble your DMF, PMF, Risk Management File, and QMS documentation with expert assistance.
Submit MD9 Application: Apply using Form MD7 on the MD Online portal once test reports are ready.
Prepare for Audit: Conduct internal audits and quality checks ahead of the CDSCO inspection.
Respond to Queries Promptly: Maintain open and prompt communication with CDSCO officials.
Taking these actionable steps early will position your company for a successful licensing outcome.
For further assistance or to initiate your application process, feel free to contact our expert regulatory team. Our proven track record in radiotherapy device licensing ensures your journey is efficient, compliant, and stress-free.