CDSCO License for Corneal scissors

Medical Device Information

Device Class
Class B

Intended Use

A hand-held, manual, ophthalmic surgical instrument intended to be  used to cut corneal tissue.

Manufacturing License
MD5
Import License
MD15
CDSCO License for Corneal scissors

Introduction to Corneal Scissors and CDSCO Regulatory Importance

Corneal scissors are precision ophthalmic surgical instruments designed for cutting corneal tissue during eye surgeries. Given their direct contact with delicate tissues and critical role in ophthalmic procedures, these devices fall under Class B risk according to the Central Drugs Standard Control Organisation (CDSCO) classification. Regulatory compliance for Corneal scissors is mandatory before marketing or manufacturing in India to ensure patient safety, device efficacy, and adherence to quality standards.

With over 25 years of experience and having supported 500+ companies in obtaining CDSCO licenses, we understand the nuances of the regulatory framework and provide actionable guidance to streamline your licensing process.

CDSCO Regulatory Framework for Corneal Scissors (Class B Medical Devices)

The notification Fts No. 29/MiscJO3/2020-DC (187) dated 9.8.2021 classifies Corneal scissors as Class B medical devices under ophthalmology. According to CDSCO, Class B devices require a manufacturing license (MD5) issued by the State Licensing Authority, involving rigorous quality, testing, and audit procedures to ensure compliance with the Medical Device Rules, 2017.

The regulatory framework covers:

  • Device classification and risk assessment
  • Manufacturing License (MD5) process
  • Documentation and audit requirements
  • Post-market surveillance obligations

Understanding this framework is critical for manufacturers and importers to avoid delays and compliance pitfalls.

Risk Classification and License Requirements for Corneal Scissors

Corneal scissors are categorized as Class B, which means moderate risk. The associated license requirements include:

  • Manufacturing License: MD5 (Application Form MD3)
  • Licensing Authority: State Licensing Authority (SLA)
  • Mandatory test license on Form MD13
  • Product testing from CDSCO-approved laboratories
  • Audit by notified bodies as per CDSCO guidelines

This classification mandates a thorough quality management system and technical documentation.

Manufacturing License Process for Corneal Scissors (MD5 License)

The MD5 licensing process is multi-step and typically takes 3-4 months from start to finish. The key steps include:

  1. Applying for Test License (Form MD13): Required before manufacturing or testing the device; takes 1.5-2 months.
  2. Product Testing: Corneal scissors must be tested at government-approved labs to verify compliance with applicable standards. Refer to the Testing Laboratories list.
  3. Documentation Preparation: Includes Device Master File, Plant Master File, risk management, essential principles checklist, and quality management records.
  4. Application Submission: Submit Form MD3 through the CDSCO MD Online Portal with all required documents.
  5. Audit by Notified Body: A notified body listed on the CDSCO Notified Bodies page conducts a detailed audit of manufacturing facilities and QMS.
  6. Resolution of Queries: Address any observations or deficiencies raised by the notified body or SLA.
  7. Grant of License: Upon satisfactory review, the SLA issues the MD5 license (Form MD5).

Manufacturing License Documents Required for Corneal Scissors

For a smooth MD5 application, the following documents must be meticulously prepared:

  • Company Constitution (Certificate of Incorporation, Partnership Deed, etc.)
  • Proof of Ownership or Lease Agreement of Manufacturing Premises
  • Details and Qualification Certificates of Technical Staff
  • Fire NOC and Pollution Control Board NOC
  • Device Master File (DMF): Detailed device design, specifications, and manufacturing processes. Our Device Master File guide provides comprehensive insights.
  • Plant Master File (PMF): Describes manufacturing site, equipment, and quality systems. Refer to our Plant Master File Guide.
  • Essential Principles Checklist verifying compliance with regulatory standards
  • Risk Management File demonstrating hazard analysis and mitigation strategies (see our Risk Management guide)
  • Product Test Reports from CDSCO-approved labs
  • Product Labels and Instructions for Use (IFU)
  • Quality Management System (QMS) Documents, including SOPs and CAPA records

Ensuring accuracy and completeness of these documents significantly reduces processing delays.

Import License Process for Corneal Scissors (Not Applicable for Manufacturing)

If you are an importer, you will need an MD15 import license from the Central Licensing Authority. The process generally takes 5-6 months and requires the following:

  • Manufacturing license from the country of origin
  • Free Sale Certificate
  • ISO 13485:2016 certification
  • CE certificate or equivalent
  • Device Master File and Plant Master File
  • Wholesale License
  • Company Constitution

Application is filed on the CDSCO MD Online Portal through Form MD14, with subsequent query resolution and license grant on Form MD15. For detailed guidance, visit our Import License Guide.

Timeline and Processing Duration for Corneal Scissors Licensing

StageDuration
Test License (MD13)1.5 - 2 months
Product Testing1 - 1.5 months
Document Preparation2 - 3 weeks
Application SubmissionImmediate (online)
Audit by Notified Body3 - 4 weeks
Queries Resolution2 - 3 weeks
License Grant (MD5)Total 3 - 4 months

Efficient coordination between testing, documentation, and audit scheduling can help optimize timelines.

Government Fees and Costs for MD5 Licensing

The fee structure for Class B devices like Corneal scissors is as follows:

  • Application Fee: Rs. 5,000 per application
  • Product-wise Fee: Rs. 500 per product

Additional costs include:

  • Laboratory testing charges (varies by test and lab)
  • Notified body audit fees (usually Rs. 20,000 to Rs. 50,000 depending on scope)
  • Consultancy or documentation preparation fees if outsourced

Budgeting for these costs upfront helps avoid surprises during the licensing journey.

Common Challenges and Practical Solutions

Challenge 1: Delays in Product Testing

  • Solution: Engage with CDSCO-approved labs early and schedule tests in advance. Use Testing Laboratories list to identify labs with shortest turnaround.

Challenge 2: Incomplete Documentation

Challenge 3: Audit Non-Conformities

  • Solution: Conduct internal audits before the notified body visit. Maintain robust QMS and ensure personnel training.

Challenge 4: Query Resolution Delays

  • Solution: Assign a dedicated regulatory expert to respond promptly and cohesively.

Expert Consultation and Support

Navigating CDSCO licensing for Corneal scissors requires specialized knowledge of regulatory nuances and procedural intricacies. Our team with 25+ years of experience offers:

  • End-to-end licensing support from document preparation to audit facilitation
  • Risk management and quality system consultancy
  • Training for technical staff on regulatory compliance
  • Post-approval support including license renewal and change management

Partnering with experts ensures your license is granted smoothly and your medical device reaches the Indian market without compliance hurdles.

Getting Started with Your CDSCO License Application for Corneal Scissors

To initiate the MD5 license application for Corneal scissors, follow these practical steps:

  1. Assess Your Facility and Staff: Confirm your manufacturing site and technical team meet CDSCO requirements.
  2. Register on CDSCO MD Online Portal: Create your account at the CDSCO MD Online Portal.
  3. Prepare Test License Application: Compile preliminary documents and submit Form MD13 for the test license.
  4. Coordinate Product Testing: Schedule testing at a CDSCO-approved lab.
  5. Develop Complete Documentation: Use our Device Master File and Plant Master File guides as templates.
  6. Apply for MD5 License: Submit Form MD3 with all required documents.
  7. Schedule and Prepare for Audit: Engage a notified body and prepare your facility.
  8. Respond to Queries Promptly: Monitor and address any observations.

Starting early and following a structured approach will minimize delays and compliance risks. For personalized assistance, contact our regulatory experts to guide you throughout the CDSCO licensing process for your Corneal scissors.


By adhering to these detailed guidelines and leveraging expert support, manufacturers and importers can confidently navigate the CDSCO licensing pathway for Corneal scissors and successfully enter the Indian ophthalmic device market.