CDSCO License for Craniotomy power tool system  handpiece

Medical Device Information

Device Class
Class C

Intended Use

Intended to be used to rotate a cranial cutting tool (i.e., a drill bit, bur, trephine or perforator) in order to produce a hole or holes in the skull vault (calvarium).

Manufacturing License
MD9
Import License
MD15
CDSCO License for Craniotomy power tool system  handpiece

Comprehensive Guide to CDSCO Licensing for Craniotomy Power Tool System Handpiece

The Craniotomy Power Tool System Handpiece is a specialized medical device classified under Class C risk by the Central Drugs Standard Control Organization (CDSCO) in India. Intended to rotate cranial cutting tools to create holes in the skull vault during neurological surgeries, this device demands stringent regulatory compliance to ensure patient safety and market access.

With over 25 years of experience and having successfully guided more than 500 companies through the CDSCO licensing process, we provide you with an in-depth, actionable roadmap tailored specifically for this Class C device. This guide covers everything from regulatory frameworks, documentation, timelines, to costs — ensuring you have a clear understanding of the requirements and best practices.


CDSCO Regulatory Framework for Craniotomy Power Tool System Handpiece

The CDSCO regulates medical devices based on risk classes, with Class C representing moderate to high risk. The Craniotomy Power Tool System Handpiece falls under the neurological category, requiring adherence to strict quality and safety standards due to its critical surgical application.

The regulatory pathway involves obtaining a manufacturing license (MD9) from the Central Licensing Authority, which oversees Class C and D devices. This process ensures the device meets the Essential Principles of Safety and Performance outlined by the CDSCO.

For online submissions, manufacturers must use the CDSCO MD Online Portal, which streamlines application tracking and communication.


Risk Classification and License Requirements for Class C Devices

The Craniotomy Power Tool System Handpiece is categorized as a Class C device because it:

  • Is invasive and used in critical neurological procedures
  • Requires high reliability and risk management

License requirement: MD9 Manufacturing License (Form MD7) granted by the central CDSCO authority.

This license ensures regulatory oversight through product testing, audits, and compliance verification.

For detailed classification criteria, refer to our Medical Device Classification guide.


Manufacturing License Process for MD9 (Class C Devices)

Obtaining the MD9 license for the Craniotomy Power Tool System follows these steps:

  1. Test License Application (Form MD13): Before full manufacturing approval, apply for a test license to produce limited quantities for testing. This stage typically takes 1.5 to 2 months.

  2. Product Testing: Conduct mandatory product testing in CDSCO-approved laboratories to validate device safety and performance. Use the list of Testing Laboratories.

  3. Document Preparation: Compile comprehensive documentation, including Device Master File and Plant Master File.

  4. Manufacturing License Application (Form MD7): Submit the MD9 application on the CDSCO portal.

  5. Audit by CDSCO Inspectors: An on-site audit verifies compliance with Good Manufacturing Practices (GMP), quality systems, and documentation.

  6. Query Resolution: Address any queries raised by the department or inspectors promptly.

  7. Grant of License (Form MD9): Upon satisfactory review and audit, the manufacturing license is issued.

The entire process typically spans 4 to 5 months when managed efficiently.

For detailed guidance, see our MD9 License Guide.


Manufacturing License Documents Required for Craniotomy Power Tool System

Ensure you have the following documents ready for submission:

  • Company Constitution Documents: Incorporation certificate, partnership deed, or equivalent
  • Proof of Premises Ownership/Lease Agreement
  • Technical Staff Qualifications: Details of qualified personnel as per CDSCO norms
  • Fire NOC and Pollution Control NOC: From local authorities
  • Device Master File (DMF): Detailed device description, specifications, manufacturing process (Device Master File guide)
  • Plant Master File (PMF): Details of manufacturing facility, quality systems (Plant Master File guide)
  • Essential Principles Checklist: Compliance matrix for safety and performance
  • Risk Management File: Per ISO 14971 principles to address potential hazards (Risk Management guide)
  • Test Reports: From CDSCO-approved labs validating device safety and effectiveness
  • Labels and Instructions for Use (IFU): As per regulatory standards
  • Quality Management System (QMS) Documents: ISO 13485 certification and SOPs

Completeness and accuracy in documentation significantly reduce processing delays.


Import License Process (MD15) for Craniotomy Power Tool System

For companies importing this device into India, an MD15 license from CDSCO’s Central Licensing Authority is mandatory.

Key steps:

  1. Document Preparation: Requires existing manufacturing license from the country of origin, Free Sale Certificate, CE Certificate (if applicable), ISO 13485:2016 certificate, Device and Plant Master Files, Wholesale License, and company constitution.

  2. License Application (Form MD14): Submit via the CDSCO MD Online Portal.

  3. Query Resolution: Respond to any clarifications from CDSCO.

  4. Grant of Import License (Form MD15): Typically issued within 5 to 6 months.

Government fees for Class C & D devices are approximately 3000persiteand3000 per site and 1500 per product.

For detailed import license insights, refer to our Import License Guide.


Timeline and Processing Duration

Process StepDuration
Test License (MD13)1.5 – 2 months
Product Testing3 – 4 weeks
Document Preparation2 – 3 weeks (varies)
Manufacturing License (MD9)2 – 3 months including audit and query resolution
Import License (MD15)5 – 6 months

Planning ahead and preparing documents meticulously can help ensure timely approvals.


Government Fees and Costs

  • MD9 Manufacturing License: ₹50,000 per application + ₹1,000 per product
  • Test License (MD13): Nominal fees applicable
  • Import License (MD15): USD 3000 per site + USD 1500 per product for Class C & D

Additional costs may include laboratory testing fees, audit charges by notified bodies, and consulting fees.


Common Challenges and Solutions

Challenge: Delays due to incomplete documentation or non-compliance during audit.

Solution: Engage expert consultants early to verify document completeness and conduct mock audits.

Challenge: Difficulty in obtaining timely test reports from government-approved labs.

Solution: Coordinate in advance and select labs with proven turnaround times from the CDSCO Testing Laboratories list.

Challenge: Navigating CDSCO portal submissions and responding to queries.

Solution: Assign dedicated regulatory personnel or partner with experienced consultants to manage online processes efficiently.


Expert Consultation and Support

Leveraging expertise is critical when dealing with complex Class C devices such as the Craniotomy Power Tool System Handpiece. Our team brings 25+ years of regulatory consulting experience, having helped over 500 manufacturers and importers obtain timely CDSCO licenses.

We offer support in:

  • Documentation preparation and review
  • Regulatory strategy and roadmap
  • Coordination with notified bodies and testing labs
  • Pre-audit readiness and mock inspections
  • CDSCO portal application management

Partnering with experts reduces risk, shortens timelines, and ensures compliance.


Getting Started with Your CDSCO License Application

  1. Assess Device Classification: Confirm your device is Class C as per CDSCO guidelines.
  2. Prepare Documentation: Begin compiling all required documents, focusing on the Device Master File and Plant Master File.
  3. Apply for Test License (MD13): Submit your initial test license application through the CDSCO MD Online Portal.
  4. Schedule Product Testing: Book slots with CDSCO-approved laboratories early to avoid bottlenecks.
  5. Develop Quality Management Systems: Ensure ISO 13485 compliance and risk management protocols are in place.
  6. Plan for Audit: Engage with notified bodies and prepare for the CDSCO inspection.

By following these steps and leveraging professional guidance, your pathway to obtaining the MD9 manufacturing license for the Craniotomy Power Tool System Handpiece will be smoother and more predictable.

For personalized assistance, reach out to our regulatory experts to initiate your application process and navigate the CDSCO landscape confidently.

Get Expert Help

Free consultation for your medical device license