CDSCO License for Flexible video gastroduodenoscope
Medical Device Information
Intended Use
An endoscope with a flexible inserted portion intended for the visual examination and treatment of the upper gastrointestinal (GI) tract [oesophagus, stomach, and duodenum (the first part of the small intestine), including the pancreas and the bile duct].

Introduction to Flexible Video Gastroduodenoscope and Regulatory Importance
Flexible video gastroduodenoscopes are vital medical devices used for detailed visual examination and therapeutic interventions in the upper gastrointestinal (GI) tract, including the oesophagus, stomach, duodenum, pancreas, and bile duct. Given their invasive nature and direct patient interaction, regulatory compliance ensures safety, efficacy, and quality, essential for gaining trust and market acceptance in India.
As regulatory consultants with over 25 years of experience and having supported 500+ companies, we understand the nuances of securing CDSCO licenses for such devices. This guide focuses on the regulatory framework, licensing process, document requirements, timelines, fees, and common challenges specific to Class B gastroenterology devices like flexible video gastroduodenoscopes.
CDSCO Regulatory Framework for Flexible Video Gastroduodenoscopes
The Central Drugs Standard Control Organization (CDSCO) governs medical device regulation in India under the Medical Device Rules, 2017. Our device falls under the notified category of Gastroenterology, with notification number 29/Misc./03/2020-DC (182) dated 27.09.2021.
Manufacturers must comply with the Medical Device Rules, including obtaining the appropriate manufacturing license (MD5 for Class A/B) or import license (MD15) before marketing the device domestically.
Risk Classification and License Requirements for Class B Gastroenterology Devices
Flexible video gastroduodenoscopes are classified as Class B devices due to moderate risk associated with their use. This classification impacts the licensing pathway:
- Manufacturing License: MD5 License (Form MD3) issued by the State Licensing Authority
- Import License: MD15 License (Form MD14) issued by the Central Licensing Authority
Class B devices require stringent documentation, product testing, and audits to ensure compliance with quality and safety standards.
Manufacturing License Process (MD5) for Flexible Video Gastroduodenoscopes
The MD5 license process is tailored for Class A and B device manufacturers and involves several key steps:
- Test License Application (Form MD13): Initiate by applying for a test license, which typically takes 1.5 to 2 months. This license permits the manufacturer to produce samples for testing.
- Product Testing: Conduct mandatory product testing at government-approved laboratories. For flexible video gastroduodenoscopes, functional, safety, and biocompatibility tests are crucial.
- Document Preparation: Prepare a comprehensive dossier including Device Master File, Plant Master File, Risk Management File, and Essential Principles Checklist.
- License Application (Form MD3): Submit the manufacturing license application through the CDSCO MD Online Portal.
- Notified Body Audit: Coordinate an audit by an accredited notified body listed on the Notified Bodies List for MD5 Audit. The audit assesses compliance with Good Manufacturing Practices (GMP) and QMS.
- Queries and Resolution: Respond promptly to any queries raised by the licensing authority or notified body.
- License Grant (Form MD5): Upon successful review and audit, the State Licensing Authority grants the MD5 manufacturing license.
Manufacturing License Documents Required for Flexible Video Gastroduodenoscopes
Preparing a robust documentation package is critical. Key documents include:
- Company Constitution (Incorporation Certificate, MOA/AOA)
- Proof of Ownership or Lease of Manufacturing Premises
- Details and Qualification Certificates of Technical Staff
- Fire and Pollution No Objection Certificates (NOCs)
- Device Master File (DMF): Detailed design and manufacturing information (Learn more about DMFs)
- Plant Master File (PMF): Factory layout, equipment, and process descriptions (PMF Guide)
- Essential Principles Checklist confirming compliance with regulatory standards
- Risk Management File documenting hazard analysis and mitigation (Risk Management Insights)
- Test Reports from CDSCO-approved testing laboratories (Testing Laboratories)
- Product Labels and Instructions for Use (IFU)
- Quality Management System (QMS) documents, ideally ISO 13485 certified
Import License Process (MD15) for Flexible Video Gastroduodenoscopes
If you are an importer intending to bring flexible video gastroduodenoscopes into India, the MD15 license is mandatory. The process includes:
- Document Compilation: Gather necessary documents such as Manufacturing License, Free Sale Certificate, ISO 13485:2016 certificate, CE Certificate, DMF, PMF, Wholesale License, and Company Constitution.
- Application Submission: File the application on the CDSCO MD Online Portal using Form MD14.
- Review and Queries: The Central Licensing Authority reviews the dossier and may raise queries.
- License Issuance: Upon satisfactory compliance, the MD15 import license is granted.
Notably, no test license is required for imports, but certification and compliance with Indian standards remain mandatory.
Import License Documents Required
For the MD15 import license specific to flexible video gastroduodenoscopes, documentation should include:
- Valid Manufacturing License from the country of origin
- Free Sale Certificate ensuring product marketability abroad
- ISO 13485:2016 Certificate
- CE Certificate or equivalent international certification
- Device Master File and Plant Master File
- Wholesale License for distribution in India
- Company Constitution and Importer Details
Timeline and Processing Duration
Understanding realistic timelines helps in strategic planning:
MD5 Manufacturing License: Approximately 3-4 months total
- Test License (MD13): 1.5-2 months
- Product Testing: 2-3 weeks
- Documentation and Application: 2-3 weeks
- Notified Body Audit and Query Resolution: 3-4 weeks
MD15 Import License: Around 5-6 months due to detailed dossier review
Planning ahead is vital; delays often occur due to incomplete documentation or delayed audit scheduling.
Government Fees and Costs
Budgeting for fees is an essential part of the license application:
- MD5 License Fees: Rs 5,000 per application plus Rs 500 per product
- MD15 Import License Fees:
- For Class B devices like flexible video gastroduodenoscopes: Rs 2,000 per site and Rs 1,000 per product
Additional costs may include testing fees at government labs, notified body audits, and consultancy fees if external help is engaged.
Common Challenges and Solutions
Manufacturers and importers often face the following issues:
- Incomplete Documentation: Missing Device or Plant Master Files often cause delays. Solution: Prepare these documents meticulously using available guides.
- Testing Delays: Limited slots at government labs can slow certification. Solution: Schedule testing early and consider alternative CDSCO-approved labs.
- Audit Scheduling: Notified bodies have limited availability. Solution: Book audits well in advance via the official notified bodies list.
- Query Responses: Delayed or insufficient responses prolong processing. Solution: Assign experienced regulatory personnel to handle queries promptly.
Expert Consultation and Support
Navigating CDSCO licensing requires expert guidance to avoid pitfalls. Our consultancy has successfully guided over 500 companies through the MD5 and MD15 licensing processes for Class B devices like flexible video gastroduodenoscopes. We assist with dossier preparation, audit readiness, test coordination, and liaising with authorities to ensure smooth approvals.
Getting Started with Your CDSCO License Application for Flexible Video Gastroduodenoscopes
To initiate your CDSCO license application, follow these actionable steps:
- Assess Your Device Classification: Confirm your device’s Class B status using the Medical Device Classification resource.
- Prepare Test License Application (for manufacturing): Apply for MD13 test license through the CDSCO MD Online Portal.
- Engage Accredited Testing Labs: Contact government-approved testing laboratories early to schedule product testing.
- Develop Complete Documentation: Utilize our comprehensive guides on Device Master File and Plant Master File preparation.
- Schedule Notified Body Audit: Refer to the Notified Bodies List and book your audit slot promptly.
- Submit Application and Track Progress: File your application via the CDSCO portal and actively monitor for queries.
Starting early and leveraging expert support significantly enhances the odds of timely CDSCO license grant, enabling you to successfully launch your flexible video gastroduodenoscope in the Indian market.
For personalized assistance and detailed regulatory strategy, contact our experienced consultants today.