CDSCO License for Foetal vacuum extraction system, pneumatic
Medical Device Information
Intended Use
To facilitate the delivery of a foetus during vaginal childbirth or Caesarean.

Understanding Foetal Vacuum Extraction System (Pneumatic) and Its Regulatory Importance
The Foetal Vacuum Extraction System (pneumatic) is a critical medical device used to assist in the delivery of a foetus during vaginal childbirth or Caesarean sections. Classified under the Obstetrical and Gynecological category, this device plays a vital role in ensuring safe delivery outcomes. Given its direct impact on maternal and neonatal safety, regulatory compliance through the Central Drugs Standard Control Organisation (CDSCO) is mandatory before manufacturing or importing this device in India.
With over 25 years of experience and having supported more than 500 companies, we understand the nuances involved in successfully navigating the CDSCO licensing process for such Class B devices. This guide offers practical, step-by-step insights into securing your MD5 manufacturing license or import license efficiently.
CDSCO Regulatory Framework for Foetal Vacuum Extraction Systems
The CDSCO regulates medical devices in India under the Medical Device Rules, 2017. The Foetal Vacuum Extraction System, being a Class B device, falls under moderate risk classification. All manufacturers or importers of this device must obtain the appropriate license to ensure compliance with safety, quality, and performance standards.
CDSCO has mandated that manufacturers of Class A and B devices apply for the MD5 license, which is issued by the State Licensing Authority. Importers must apply for the MD15 import license through the Central Licensing Authority. The regulatory framework ensures that devices meet the Essential Principles of Safety and Performance.
Risk Classification and License Requirements for Foetal Vacuum Extraction System
According to the official notification (File No. 29/Misc./03/2020-DC (181), dated 03.06.2022), the Foetal Vacuum Extraction System (pneumatic) is classified as a Class B device. This classification is critical as it determines the licensing pathway:
- Manufacturing License: MD5 License (Application Form MD3) via State Licensing Authority
- Import License: MD15 License via Central Licensing Authority
You can verify device classifications on our detailed Medical Device Classification guide.
Manufacturing License Process for Foetal Vacuum Extraction System (MD5 License)
For manufacturers planning to produce the Foetal Vacuum Extraction System within India, the MD5 license process is mandatory. Here's the practical roadmap:
- Apply for Test License (Form MD13): Before manufacturing, obtain a test license allowing product testing. This typically takes 1.5 to 2 months.
- Product Testing: Get your device tested at government-approved laboratories. Refer to the CDSCO Testing Laboratories list for authorized labs.
- Document Preparation: Prepare comprehensive documentation including Device Master File, Plant Master File, Risk Management File, Essential Principles Checklist, and QMS documents.
- Apply for Manufacturing License (Form MD3): Submit the MD5 application through the CDSCO MD Online Portal.
- Audit by Notified Body: An audit conducted by a CDSCO-notified body verifies compliance. Check the Notified Bodies List to select an auditor.
- Query Resolution: Address any queries from the licensing authority or audit team promptly.
- Grant of License (Form MD5): Upon successful completion, the license is issued.
Our detailed MD5 License Guide covers all these steps in depth.
Manufacturing License Documents Required for Foetal Vacuum Extraction System
A successful MD5 license application must include the following documents:
- Company Constitution (Incorporation Certificate, Memorandum & Articles of Association)
- Proof of Ownership or Lease of Manufacturing Premises
- Details and Qualifications of Technical Staff
- Fire No Objection Certificate (NOC)
- Pollution Control Board NOC
- Device Master File (DMF) – design, manufacturing process, and specifications. Our Device Master File Guide explains this thoroughly.
- Plant Master File (PMF) – details of infrastructure and quality control systems. See our Plant Master File Guide.
- Essential Principles Checklist confirming compliance with safety and performance requirements
- Risk Management File as per ISO 14971 standards. Learn about Risk Management.
- Test Reports from CDSCO-approved labs
- Product Labels and Instructions for Use (IFU)
- Quality Management System (QMS) Documents (ISO 13485:2016 certification is strongly recommended)
Import License Process for Foetal Vacuum Extraction System (MD15 License)
Importers seeking to bring the Foetal Vacuum Extraction System into India must obtain the MD15 import license from the Central Licensing Authority. The process is as follows:
- Document Preparation: Compile all necessary certificates and documents, including manufacturing license from the country of origin, Free Sale Certificate, ISO 13485 certificate, CE Certificate, Device Master File, Plant Master File, and wholesale license.
- Application Submission: Submit the application on CDSCO MD Online Portal using Form MD14.
- Query Resolution: Respond to any queries or requests for additional information from CDSCO.
- License Grant: After satisfying all regulatory requirements, the MD15 license is issued.
For detailed import license process insights, refer to our Import License Guide.
Import License Documents Required for Foetal Vacuum Extraction System
The following documents are essential for the MD15 import license application:
- Valid Manufacturing License from the Country of Origin
- Free Sale Certificate
- ISO 13485:2016 Certification
- CE Certificate or Equivalent
- Device Master File
- Plant Master File
- Wholesale License under Drugs and Cosmetics Act
- Company Constitution Documents
Timeline and Processing Duration
For a Foetal Vacuum Extraction System (Class B device), the typical timelines are:
License Type | Estimated Duration |
---|---|
Test License (MD13) | 1.5 to 2 months |
Product Testing | 1 to 1.5 months |
MD5 Manufacturing License | 3 to 4 months total (including audit and queries) |
MD15 Import License | 5 to 6 months |
Being proactive in document preparation and prompt in query resolution can significantly reduce delays.
Government Fees and Costs
The fee structure for the Foetal Vacuum Extraction System is as follows:
MD5 Manufacturing License:
- Application Fee: Rs. 5,000
- Per Product Fee: Rs. 500
MD15 Import License:
- For Class B devices:
- Site Fee: $2,000
- Per Product Fee: $1,000
- For Class B devices:
Note that additional costs may include expenses related to product testing, notified body audits, and consultant fees.
Common Challenges and Solutions
Challenge 1: Delays in Product Testing Many applicants underestimate the time required for testing at government-approved labs. We recommend initiating testing immediately after securing the test license to avoid bottlenecks.
Solution: Engage with testing laboratories early and confirm sample requirements and timelines upfront.
Challenge 2: Incomplete Documentation Incomplete or inconsistent documentation leads to repeated queries and delays.
Solution: Utilize comprehensive checklists and templates for Device and Plant Master Files, and ensure alignment with ISO standards.
Challenge 3: Audit Non-Compliance Failure to comply with notified body audit requirements can stall license issuance.
Solution: Prepare thoroughly for audits by conducting internal pre-audits and training staff on regulatory expectations.
Expert Consultation and Support
Navigating CDSCO licensing for the Foetal Vacuum Extraction System requires expertise in regulatory nuances and documentation. Our team has supported 500+ companies in securing MD5 and MD15 licenses efficiently. We offer:
- End-to-end application preparation and submission
- Gap analysis and corrective action planning
- Liaison with CDSCO and notified bodies
- Training on regulatory compliance and quality systems
Connect with us early in your project to leverage our deep knowledge and avoid costly delays.
Getting Started with Your CDSCO License Application
- Classify Your Device: Confirm your device's risk class and licensing requirement. For the Foetal Vacuum Extraction System, this is Class B, requiring an MD5 license for manufacturing.
- Gather Your Team: Assign roles for regulatory affairs, quality assurance, and technical documentation.
- Prepare Preliminary Documentation: Begin compiling your Device Master File, Plant Master File, and Risk Management File.
- Apply for Test License: Submit Form MD13 via the CDSCO MD Online Portal to initiate product testing.
- Plan for Testing and Audit: Schedule government-approved lab testing and select a notified body for the audit.
- Seek Professional Assistance: Consider expert regulatory consultancy to streamline the process and ensure compliance.
By following these actionable steps and leveraging our extensive experience, you can successfully obtain your CDSCO license for the Foetal Vacuum Extraction System and bring your product to the Indian market with confidence.