Logo
Chat on WhatsApp

CDSCO License for Impedance audiometer

Medical Device Information

Device Class
Class B

Intended Use

Intended to evaluate the functional condition of the middle ear by changing the air pressure in the external auditory canal to measure and graph the mobility characteristics of the tympanic membrane.

Manufacturing License
MD5
Import License
MD15
CDSCO License for Impedance audiometer

Comprehensive Guide to CDSCO Licensing for Impedance Audiometers (Class B ENT Device)

As a trusted regulatory consulting firm with over 25 years of experience and having assisted more than 500 companies in successfully obtaining CDSCO licenses, we understand the intricacies involved in navigating India's medical device regulatory landscape. This guide provides detailed insights specific to the Impedance Audiometer, a Class B medical device used to evaluate middle ear function.

Understanding the Impedance Audiometer and Its Regulatory Importance

The Impedance Audiometer plays a critical role in otolaryngology by measuring the mobility of the tympanic membrane via changes in air pressure in the external auditory canal. Given its diagnostic function, the device falls under the Class B risk category as per the CDSCO notification [29/Misc/03/2020-DC(196)] dated 06.08.2021. Compliance with CDSCO regulations ensures patient safety, device efficacy, and market authorization to distribute in India.

CDSCO Regulatory Framework for Impedance Audiometers (Class B ENT Devices)

Medical devices in India are regulated by the Central Drugs Standard Control Organization (CDSCO) under the Ministry of Health and Family Welfare. Class B devices, including the Impedance Audiometer, require a manufacturing license (MD5) issued by the State Licensing Authority. The process involves multiple steps such as obtaining a test license, product testing, documentation, and audit by a notified body.

Risk Classification and License Requirements for the Impedance Audiometer

  • Device Risk Class: B
  • License Type: MD5 (Manufacturing License for Class A and B devices)
  • Application Form: MD3
  • Regulatory Authority: State Licensing Authority
  • Total Processing Time: Approximately 3-4 months

For a detailed understanding of medical device classification in India, refer to our Medical Device Classification guide.

Manufacturing License Process (MD5) for Impedance Audiometer

The MD5 licensing process involves the following steps:

  1. Obtain Test License (Form MD13): Apply for a test license, valid typically for 6 months, allowing the device to undergo mandatory testing in CDSCO-approved labs.
  2. Product Testing: Submit the Impedance Audiometer to government-approved laboratories to obtain test reports validating compliance with essential principles.
  3. Documentation Preparation: Compile necessary technical and quality documents including Device Master File (DMF), Plant Master File (PMF), Risk Management File, and Essential Principles Checklist.
  4. Application Submission: Submit the manufacturing license application via the CDSCO MD Online Portal using Form MD3.
  5. Audit by Notified Body: Undergo a thorough audit by a notified body selected from the official list of notified bodies.
  6. Resolution of Queries: Address any queries raised by the licensing authority or notified body during the review period.
  7. Grant of License: On successful completion of all steps, the license is granted on Form MD5.

For an in-depth walkthrough, our MD5 License Guide offers comprehensive assistance.

Manufacturing License Documents Required for the Impedance Audiometer

The documentation package for the MD5 license must be meticulously prepared and typically includes:

  • Company Constitution (Incorporation Certificate, MOA/AOA)
  • Proof of ownership or lease agreement for manufacturing premises
  • Details and qualifications of technical staff
  • Fire and Pollution NOCs
  • Device Master File (DMF): Detailed device specifications and design (Guide to DMF)
  • Plant Master File (PMF): Manufacturing site and process details (PMF Guide)
  • Essential Principles Checklist demonstrating compliance with safety and performance
  • Risk Management File highlighting identified risks and mitigation strategies (Risk Management Guide)
  • Test Reports from CDSCO-approved labs (Testing Laboratories List)
  • Product Labels and Instructions for Use (IFU)
  • Quality Management System (QMS) documentation, typically ISO 13485:2016 compliant

Import License Process (MD15) for Impedance Audiometer

While this guide focuses on manufacturing licensing, importers of the Impedance Audiometer must obtain an MD15 import license from the Central Licensing Authority. The process involves:

  • Preparing import-specific documentation including Free Sale Certificate, ISO 13485:2016, CE Certificate, and existing manufacturing license
  • Applying through Form MD14 on the CDSCO portal
  • Responding to queries within stipulated timelines
  • License issuance on Form MD15

For importers, our detailed Import License Guide can significantly streamline the process.

Timeline and Processing Duration for the MD5 License

StepDuration
Test License Application1.5 - 2 months
Product Testing2 - 3 weeks
Documentation Preparation2 - 4 weeks
MD5 Application & Audit1.5 - 2 months
Query Resolution2 - 4 weeks

Total estimated timeline: 3 to 4 months from start to finish.

Government Fees and Costs for Impedance Audiometer Licensing

Fee TypeAmount (INR)
Application Fee5,000
Per Product Fee500

For example, if you are applying for three variants of the Impedance Audiometer, the total government fee will be INR 5,000 + (3 x 500) = INR 6,500.

Additional costs include testing fees at government-approved labs, notified body audit charges, and consultancy fees if you engage professional support.

Common Challenges and Practical Solutions

  • Complex Documentation: Manufacturers often struggle with compiling comprehensive DMF and PMF. We recommend early preparation using templates and expert reviews.
  • Test Lab Delays: To avoid bottlenecks, schedule product testing well in advance and select labs from the official Testing Laboratories list.
  • Audit Non-compliance: Ensure your QMS and manufacturing processes are audit-ready; pre-audit internal checks can prevent surprises.
  • Query Management: Prompt and concise responses to CDSCO queries can significantly reduce overall timelines.

Expert Consultation and Support

With over 25 years of domain expertise, we offer end-to-end support including:

  • Regulatory strategy development
  • Document preparation and review
  • Liaison with CDSCO and notified bodies
  • Audit readiness and gap analysis
  • Post-license compliance and renewal assistance

Our proven track record in assisting over 500 companies ensures that your Impedance Audiometer licensing journey is smooth and efficient.

Getting Started with Your CDSCO License Application

  1. Initiate Internal Assessment: Verify your device’s classification and prepare a list of required documents.
  2. Apply for Test License (MD13): Submit the test license application via the CDSCO MD Online Portal.
  3. Plan Product Testing: Book slots at government-approved testing laboratories early.
  4. Prepare Documentation: Use our DMF and PMF guides to create compliant files.
  5. Engage a Notified Body: Identify and appoint a notified body from the official list for audit scheduling.
  6. Submit MD5 Application: Once testing and documentation are complete, apply through the CDSCO portal with Form MD3.
  7. Track Application Status: Respond promptly to any queries to avoid delays.

Embarking on the CDSCO licensing journey for your Impedance Audiometer need not be daunting. With meticulous planning and expert guidance, you can achieve timely market access and compliance. Contact us to leverage our extensive expertise and accelerate your device’s approval in the Indian market.

Get Expert Help

Free consultation for your medical device license

24/7 Support Available

Why Choose Us

500+ Licenses Obtained
100% Success Rate
15+ Years Experience
24/7 Support Available

About the Author

avatar
Tails Azimuth
@Twitter