CDSCO License for Medical neutron radiation therapy system
Medical Device Information
Intended Use
A medical neutron radiation therapy system is a device intended to generate high-energy neutrons for radiation therapy

Comprehensive Guide to CDSCO Licensing for Medical Neutron Radiation Therapy Systems (Class C Radiotherapy Device)
Medical neutron radiation therapy systems are specialized Class C medical devices designed to generate high-energy neutrons for targeted radiation therapy in oncology. Given their critical role and inherent risks, regulatory compliance with the Central Drugs Standard Control Organization (CDSCO) in India is mandatory before manufacturing or importing such devices.
With over 25 years of experience assisting 500+ companies in securing CDSCO approvals, we provide a detailed walkthrough of the regulatory framework, licensing procedures, and practical insights to streamline your application for this high-risk radiotherapy equipment.
CDSCO Regulatory Framework for Medical Neutron Radiation Therapy Systems
The CDSCO classifies medical devices based on risk. Neutron radiation therapy systems fall under Class C, indicating moderate to high risk, especially because of their potential impact on patient safety and radiation exposure.
The licensing for Class C devices is governed centrally by CDSCO’s Medical Device Division, requiring the MD9 manufacturing license for domestic production and the MD15 import license for imported devices. These licenses ensure compliance with Indian safety standards, Good Manufacturing Practices (GMP), and thorough technical evaluation.
The relevant notification governing this device is File No. 29/Misc./03/2020-DC (180) dated 6.8.2021, confirming its classification and regulatory pathway.
Risk Classification and License Requirements for Class C Devices
Class C devices like neutron radiation therapy systems require:
- MD9 Manufacturing License (Application Form MD7) issued by the Central Licensing Authority
- A prior Test License (MD13) for product testing
- Compliance with Indian and international standards such as ISO 13485:2016 and IEC radiation safety norms
- Rigorous documentation including Device Master File (DMF) and Plant Master File (PMF)
This centralized process ensures a stringent evaluation, including product testing and factory audits.
Manufacturing License Process (MD9) for Medical Neutron Radiation Therapy Systems
The MD9 licensing process generally spans 4 to 5 months and involves several critical steps:
Test License Application (MD13 Form): Submit an application for a test license to allow product testing in CDSCO-approved laboratories. This step takes about 1.5 to 2 months.
Product Testing: Conduct mandatory testing at government-approved labs to validate device safety and performance. A list of CDSCO-approved testing laboratories is available for reference.
Document Preparation: Assemble comprehensive documentation, including the Device Master File, Plant Master File, Quality Management System (QMS) documents, risk management files, and proof of compliance with essential principles.
License Application Submission: Apply for the manufacturing license via the CDSCO MD Online Portal using Form MD7.
Factory Audit: CDSCO inspectors conduct a detailed audit of manufacturing facilities and QMS systems.
Query Resolution: Address any queries from the department or inspectors promptly.
Grant of MD9 License: Once all criteria are satisfied, the license is granted on Form MD9.
For detailed guidance on this process, refer to our MD9 license guide.
Manufacturing License Documents Required
To ensure a smooth approval, the following documents must be meticulously prepared:
- Company Constitution Documents: Certificate of Incorporation, Memorandum and Articles of Association
- Proof of Premises Ownership or Lease Agreement
- Technical Staff Credentials: Qualifications and experience of key personnel
- Fire and Pollution NOC: Obtained from local authorities
- Device Master File (DMF): Detailed product design, specs, manufacturing processes (See DMF Guide)
- Plant Master File (PMF): Facility layout, equipment details, quality controls (See PMF Guide)
- Essential Principles Compliance Checklist
- Risk Management File: Hazard analysis and mitigation plans (Risk Management Reference)
- Test Reports: From CDSCO-approved laboratories
- Product Labels and Instructions for Use (IFU)
- Quality Management System Documents: ISO 13485:2016 certification and SOPs
Preparing these documents with precision minimizes delays during audit and query resolution.
Import License Process (MD15) for Medical Neutron Radiation Therapy Systems
Importing Class C devices demands an MD15 license, a rigorous process handled by the Central Licensing Authority with an estimated timeline of 5 to 6 months.
Key steps include:
- Preparation of required import documentation
- Submission of application on the CDSCO MD Online Portal via Form MD14
- Review and query resolution by CDSCO officials
- License grant on Form MD15
Unlike manufacturing, an MD15 license does not require a test license but mandates submission of certificates such as Free Sale Certificate, CE Marking, and ISO 13485:2016.
Import License Documents Required
The documentation for import license includes:
- Valid Manufacturing License from the country of origin
- Free Sale Certificate from the regulatory authority of the exporting country
- ISO 13485:2016 Certificate
- CE Certificate or equivalent international certification
- Device Master File and Plant Master File
- Wholesale license (if applicable)
- Company Constitution Documents
For a comprehensive checklist and expert support, visit our Import License Guide.
Timeline and Processing Duration
License Type | Process Duration |
---|---|
MD13 Test License | 1.5 - 2 months |
MD9 Manufacturing License | 4 - 5 months total (including test license) |
MD15 Import License | 5 - 6 months |
Planning your application timeline accordingly is crucial to avoid costly delays in market entry.
Government Fees and Costs
License Type | Application Fee | Per Product Fee |
---|---|---|
MD5 (Class A/B) | Rs 5000 | Rs 500 |
MD9 (Class C/D) | Rs 50,000 | Rs 1000 |
MD15 (Import) | Class C: $3000 per site | $1500 per product |
Note: Fees are subject to change; always verify on the CDSCO MD Online Portal.
Common Challenges and Solutions
Challenge: Delays due to incomplete documentation or non-compliance with essential principles.
Solution: Engage experienced consultants early and use checklists to ensure document completeness.
Challenge: Audit failures due to inadequate QMS or facility readiness.
Solution: Conduct internal pre-audits and train staff on audit protocols.
Challenge: Prolonged product testing phase.
Solution: Select CDSCO-approved labs with proven turnaround times; consider parallel documentation preparation.
Expert Consultation and Support
Navigating the CDSCO licensing landscape for complex Class C devices can be daunting. Our team, with over 25 years of regulatory experience and a track record of 500+ successful approvals, offers:
- Customized documentation preparation
- Liaison with CDSCO officials and notified bodies
- Pre-audit readiness assessments
- End-to-end project management to expedite approvals
Reach out for a consultation to leverage our expertise in accelerating your device’s market access.
Getting Started with Your CDSCO License Application
Assess and Confirm Device Classification: Review your device under the CDSCO classification system (Medical Device Classification) to reaffirm Class C status.
Initiate Test License Application (MD13): Register and submit your test license application via the CDSCO MD Online Portal.
Prepare Documentation: Start compiling required documents—Device Master File, Plant Master File, QMS certificates, and risk management files.
Coordinate Product Testing: Engage with approved labs early to schedule testing.
Plan for Audit: Ensure your manufacturing facility and QMS are audit-ready.
Submit MD9 Application: After successful testing, apply for the manufacturing license with Form MD7.
Respond Promptly to Queries: Expedite query resolution to avoid unnecessary delays.
By following these actionable steps and leveraging expert support, manufacturers and importers can efficiently navigate the CDSCO regulatory pathway for medical neutron radiation therapy systems and confidently enter the Indian healthcare market.