Class A Non-sterile Non Measuring devices are exempt from MD5 and MD15 licenses. Only CDSCO registration is required as per GSR 777(E).
Intended Use
An illuminator device intended to providing optimial light and colour renderingn to aid in performing surgery.

Introduction to Surgical Light Systems and Their Regulatory Importance
Surgical light systems are essential operation theatre devices designed to provide optimal illumination and accurate colour rendering, enabling surgeons to perform precise procedures. Given their critical role in patient safety and surgical outcomes, regulatory oversight by the Central Drugs Standard Control Organization (CDSCO) is mandatory to ensure these devices meet stringent quality and safety standards before entering the Indian market.
With over 25 years of experience and having supported 500+ companies in navigating CDSCO licensing, we understand the nuances involved in securing approvals for Class A medical devices like surgical light systems. This comprehensive guide will walk you through the CDSCO regulatory framework, licensing processes, document requirements, timelines, and practical advice tailored specifically for your device.
CDSCO Regulatory Framework for Surgical Light Systems
Surgical light systems fall under the Operation Theatre category and are classified as Class A (low risk) medical devices as per the notification File No. 29/Misc/03/2020-DC (199), dated 13.9.2021. Class A devices require compliance with the Medical Device Rules 2017 (amended) and must obtain a manufacturing license (MD5) from the State Licensing Authority before marketing.
The regulatory framework mandates conformity to essential principles of safety and performance, supported by documentation such as Device Master File (DMF), Plant Master File (PMF), and Quality Management System (QMS) certifications.
Risk Classification and License Requirements for Surgical Light Systems
- Risk Class: A (Low Risk)
- License Type: MD5 (Manufacturing License for Class A/B devices)
- Regulatory Authority: State Licensing Authority
- Relevant Application Form: MD3 for manufacturing license
Class A devices like surgical light systems require a test license (MD13) prior to the MD5 application, enabling product testing at government-approved laboratories. The entire licensing process, including testing, audit, and license grant, typically spans 3-4 months.
For detailed classification, manufacturers can refer to the Medical Device Classification guide.
Manufacturing License Process (MD5) for Surgical Light Systems
- Apply for Test License (Form MD13): Submit application via the CDSCO MD Online Portal to obtain a test license, allowing product testing to verify compliance.
- Product Testing: Conduct tests at government-approved labs listed on the CDSCO Testing Laboratories page. Testing typically takes 4-6 weeks.
- Document Preparation: Compile required documents including Device Master File, Plant Master File, Essential Principles Checklist, Risk Management File, and QMS documents.
- Submit Manufacturing License Application (Form MD3): Apply for MD5 license through the CDSCO portal.
- Audit by Notified Body: Coordinate with a notified body (refer to the List of Notified Bodies) for factory audit and compliance verification.
- Resolve Queries: Address any observations or queries from CDSCO or the notified body promptly.
- Grant of License (Form MD5): Upon satisfactory compliance, the State Authority issues the manufacturing license.
For a detailed stepwise explanation, our MD5 License Guide offers in-depth insights.
Manufacturing License Documents Required for Surgical Light Systems
- Company Constitution (Incorporation Certificate, MOA/AOA)
- Proof of Ownership or Lease Agreement of Manufacturing Premises
- Details and Qualifications of Technical Staff
- Fire Safety NOC
- Pollution Control Board NOC
- Device Master File (DMF) – detailed device description, design, manufacturing process (Device Master File Guide)
- Plant Master File (PMF) – manufacturing facility details (Plant Master File Guide)
- Essential Principles Checklist confirming compliance to safety and performance standards
- Risk Management File demonstrating hazard analysis and mitigation (Risk Management Guide)
- Test Reports from CDSCO-approved laboratories
- Labels and Instructions for Use (IFU)
- Quality Management System (QMS) documentation (ISO 13485:2016 certification preferred)
Properly organizing these documents reduces processing delays and facilitates smoother audits.
Import License Process (MD15) for Surgical Light Systems
While your device is Class A and primarily requires an MD5 manufacturing license if produced domestically, importers seeking to bring surgical light systems into India must apply for an Import License (MD15) from the Central Licensing Authority.
The MD15 process involves:
- Document preparation including Manufacturing License from the country of origin, Free Sale Certificate, ISO 13485 certification, CE Certificate, DMF, PMF, and company constitution.
- Submission of application on the CDSCO MD Online Portal.
- Addressing queries from CDSCO.
The MD15 license typically takes 5-6 months. For more detailed insights, refer to our Import License Guide.
Import License Documents Required
- Valid Manufacturing License from the country of origin
- Free Sale Certificate
- ISO 13485:2016 Certificate
- CE Certificate or equivalent
- Device Master File and Plant Master File
- Wholesale License (if applicable)
- Company Constitution
- Detailed Product Description and Intended Use
Timeline and Processing Duration
Process Step | Duration |
---|---|
Test License (MD13) | 1.5 - 2 months |
Product Testing | 1 - 1.5 months |
Document Preparation | 2 - 3 weeks |
License Application (MD3) | Immediate |
Audit by Notified Body | 3 - 4 weeks |
Query Resolution | 2 - 3 weeks |
Grant of MD5 License | Within 3 - 4 months total |
Planning for a total of 3-4 months from start to finish ensures realistic expectations and resource allocation.
Government Fees and Costs
- Test License Fee: Included in the overall process
- MD5 Manufacturing License Fee: Rs. 5,000 per application + Rs. 500 per product
- Product Testing Costs: Vary depending on laboratory and tests required; typically Rs. 50,000 to Rs. 1,00,000 per product
- Audit Fees: Paid to Notified Bodies separately (varies by body and scope)
Budgeting for these expenses upfront will help avoid last-minute financial bottlenecks.
Common Challenges and Practical Solutions
Challenge | Solution |
---|---|
Incomplete or inconsistent documentation | Engage expert consultants; use checklists |
Delays in product testing | Schedule testing early; choose accredited labs |
Non-compliance during audit | Pre-audit internal inspections; train staff |
Query resolution delays | Respond promptly with detailed explanations |
Understanding regulatory updates | Regularly monitor CDSCO notifications and guidance |
Our extensive experience enables us to anticipate and mitigate such hurdles efficiently.
Expert Consultation and Support
Navigating CDSCO licensing can be complex, especially for first-time applicants. Leveraging expert consultants with proven track records can streamline the process, reduce errors, and expedite approvals. We provide end-to-end support including:
- Gap analysis and readiness assessment
- Documentation preparation and review
- Coordination with testing laboratories and notified bodies
- Audit preparation and training
- Query handling and follow-up
Contacting seasoned professionals early can save months of delays and costly rework.
Getting Started with Your CDSCO License Application for Surgical Light Systems
- Register on the CDSCO MD Online Portal: Begin by creating your company profile and submitting the test license (MD13) application.
- Engage a Testing Laboratory: Identify and schedule testing with an approved lab from the CDSCO Testing Laboratories list.
- Prepare Documentation: Simultaneously start compiling your Device Master File, Plant Master File, Risk Management File, and QMS documents.
- Plan for Audit: Shortlist notified bodies for the audit and schedule accordingly.
- Monitor and Follow-Up: Track application status, respond to queries promptly, and maintain transparent communication with CDSCO.
By following these actionable steps and leveraging expert guidance, manufacturers and importers of surgical light systems can confidently approach the Indian regulatory landscape and successfully obtain the required CDSCO MD5 license.
For more detailed assistance and personalized consultation, please reach out to our regulatory experts.
Note: Always refer to the latest CDSCO guidelines and notifications as regulations may evolve.