CDSCO License for Behind-the-ear bone- conduction tinnitus masker
Medical Device Information
Intended Use
Intended to provide ultrasonic broadband noise and/or sweep-frequency stimuli noise of sufficient intensity and bandwidth to mask tinnitus.

Introduction to Behind-the-Ear Bone-Conduction Tinnitus Masker and Its Regulatory Importance
The behind-the-ear bone-conduction tinnitus masker is a specialized Class C medical device designed to help patients manage tinnitus by delivering ultrasonic broadband noise and sweep-frequency stimuli noise. This device, classified under the ENT category, works by masking tinnitus symptoms, thereby improving patient quality of life. Given its risk classification and medical application, regulatory compliance with the Central Drugs Standard Control Organization (CDSCO) is mandatory for any manufacturer or importer aiming to market this device in India.
Navigating the CDSCO regulatory landscape can be complex, especially for Class C devices like this tinnitus masker. Drawing on our 25+ years of experience and having supported over 500 companies successfully, we provide practical, detailed guidance through the entire licensing process, ensuring you avoid common pitfalls and delays.
CDSCO Regulatory Framework for Behind-the-Ear Bone-Conduction Tinnitus Masker
The CDSCO categorizes medical devices based on risk, intended use, and complexity. Being a Class C device, the behind-the-ear bone-conduction tinnitus masker falls under moderate-to-high risk devices. The regulatory framework mandates manufacturers and importers to obtain a manufacturing license (MD9) or import license (MD15) from the Central Licensing Authority.
The regulatory notification governing this device is 29/Misc/03/2020-DC(196), dated 06.08.2021. Compliance with this notification and relevant Indian standards ensures market authorization.
Risk Classification and License Requirements for Class C ENT Devices
As a Class C device, the tinnitus masker requires:
- Manufacturing License (MD9): If manufactured in India.
- Import License (MD15): If imported.
Class C devices are subject to a higher degree of scrutiny than Class A or B, including mandatory clinical evaluation, stricter documentation, and audits by CDSCO inspectors.
For detailed classification criteria, please refer to our Medical Device Classification guide.
Manufacturing License Process (MD9) for Behind-the-Ear Bone-Conduction Tinnitus Masker
The MD9 license process involves several key steps:
Test License Application (Form MD13): Initiate by applying for a test license, which takes approximately 1.5 to 2 months. This allows you to manufacture the device for testing purposes.
Product Testing: Conduct mandatory product testing at CDSCO-approved laboratories to ensure compliance with Indian standards. A list of approved testing laboratories is available for your convenience.
Document Preparation: Prepare comprehensive documentation, including Device Master File, Plant Master File, Essential Principles Checklist, and Risk Management File.
Application Submission: Apply for the MD9 license using Form MD7 through the CDSCO MD Online Portal.
Audit by CDSCO Inspectors: The authorities will conduct an audit of your manufacturing site and quality management system.
Query Resolution: Address any questions or clarifications raised by the CDSCO or auditors promptly.
License Grant: Upon satisfactory review, the MD9 manufacturing license is granted.
The entire process typically spans 4 to 5 months, assuming timely compliance and documentation.
For a detailed procedural overview, refer to our MD9 License Guide.
Manufacturing License Documents Required for MD9
You will need to submit the following:
- Company Constitution Documents: Incorporation certificate, memorandum of association.
- Proof of Premises Ownership or Lease Agreement.
- Technical Staff Qualifications and Experience Details.
- Fire and Pollution No Objection Certificates (NOCs).
- Device Master File: Detailed device description, design, manufacturing process. Learn more from our Device Master File guide.
- Plant Master File: Details of manufacturing facilities and quality systems. Refer to our Plant Master File guide.
- Essential Principles Checklist: Compliance checklist per CDSCO requirements.
- Risk Management File: Documented risk analysis and mitigation strategies. See our Risk Management resource.
- Test Reports: From CDSCO-approved laboratories.
- Labels and Instructions for Use (IFU).
- Quality Management System (QMS) Documents: ISO 13485 certification and procedures.
Import License Process (MD15) for Behind-the-Ear Bone-Conduction Tinnitus Masker
If you intend to import the device, the MD15 import license is required. The process includes:
Document Preparation: Ensure you have all required documents including manufacturing license from the country of origin, Free Sale Certificate, ISO 13485:2016, CE Certificate, and others.
Application Submission: File Form MD14 on the CDSCO MD Online Portal.
Queries and Clarifications: Address any queries raised by CDSCO.
License Issuance: Upon satisfactory evaluation, MD15 license is granted.
The import license process typically takes 5 to 6 months.
Refer to our comprehensive Import License Guide for detailed insights.
Import License Documents Required for MD15
Prepare the following documents:
- Valid manufacturing license from the country of origin.
- Free Sale Certificate.
- ISO 13485:2016 Certification.
- CE Certificate or equivalent regulatory approval.
- Device Master File.
- Plant Master File.
- Wholesale license.
- Company constitution documents.
Timeline and Processing Duration
License Type | Approximate Duration |
---|---|
Test License (MD13) | 1.5 to 2 months |
Manufacturing License (MD9) | 4 to 5 months (including test license and audit) |
Import License (MD15) | 5 to 6 months |
Planning your submissions with these timelines in mind is critical to market entry success.
Government Fees and Costs for Class C Devices
MD9 Manufacturing License:
- Application fee: ₹50,000
- Per product fee: ₹1,000
MD15 Import License:
- Application fee: ₹3,000 (per site)
- Per product fee: ₹1,500
Additional costs include laboratory testing fees, notified body audit charges, and consultancy fees if applicable.
Common Challenges and Practical Solutions
Delayed document preparation: Begin early and use checklists to ensure completeness.
Audit non-compliance: Conduct mock audits internally or with consultants to prepare.
Test report delays: Choose CDSCO-approved labs with proven turnaround times from the Testing Laboratories list.
Query management: Assign a dedicated team member to respond promptly to CDSCO queries.
Compliance with risk management: Implement robust risk management per ISO 14971 standards.
Expert Consultation and Support
With over 25 years of experience and a track record of guiding 500+ companies, we specialize in CDSCO licensing for Class C devices. Our expert consultants assist with:
- Licensing strategy and classification advice.
- Documentation preparation, including Device and Plant Master Files.
- Coordination with CDSCO, notified bodies, and testing labs.
- Audit readiness and risk management implementation.
Partnering with us mitigates risks of delays, non-compliance, and costly reworks.
Getting Started with Your CDSCO License Application for Behind-the-Ear Bone-Conduction Tinnitus Masker
- Assess your device classification and intended activities (manufacturing or import).
- Gather all mandatory documents outlined above.
- Apply for the test license (MD13) if manufacturing.
- Schedule product testing with CDSCO-approved labs.
- Engage a notified body for audit preparation if applying for MD9. Check the list of notified bodies.
- Submit your application on the CDSCO MD Online Portal.
- Prepare for and respond promptly to any queries or audit findings.
Taking these actionable steps will streamline your journey to obtaining CDSCO approval, enabling you to bring your behind-the-ear bone-conduction tinnitus masker to the Indian market confidently and compliantly.