CDSCO License for Laryngectomy tube
Medical Device Information
Intended Use
A device intended to maintain tracheostoma patency after laryngectomy to provide an airway for the patient and to prevent tracheostomal stenosis in the months following the procedure.

Comprehensive Guide to CDSCO Licensing for Laryngectomy Tube (Class B Medical Device)
As seasoned regulatory consultants with over 25 years of experience and a track record of assisting 500+ companies, we understand the nuances and critical requirements for obtaining CDSCO approval for medical devices like the Laryngectomy Tube. This device, classified as Class B under the anesthesiology category, plays a vital role in maintaining tracheostoma patency post-laryngectomy, thus ensuring patient airway management and preventing tracheostomal stenosis.
Understanding the CDSCO Regulatory Framework for Laryngectomy Tubes
The Central Drugs Standard Control Organization (CDSCO) governs the regulation of medical devices in India, ensuring safety, quality, and efficacy. For devices like the Laryngectomy Tube, falling under Class B, the regulatory oversight is managed primarily at the State level via the MD5 license process. This process demands stringent compliance with documentation, testing, and quality management standards.
Risk Classification and License Requirements for Laryngectomy Tube
According to the latest CDSCO notification (29/Misc/03/2020-DC(177) dated 12.07.2021), the Laryngectomy Tube is a Class B device. Class B devices are considered low-moderate risk, requiring manufacturers to obtain an MD5 license from the State Licensing Authority. This ensures that the manufacturing site complies with applicable standards and that the product is safe for clinical use.
For a detailed understanding of device classifications, manufacturers can refer to the Medical Device Classification guide.
Step-by-Step Manufacturing License Process (MD5) for Class B Devices
Test License Application (Form MD13):
- Before applying for the manufacturing license, companies must secure a test license, typically taking 1.5 to 2 months.
- This allows testing of the Laryngectomy Tube in CDSCO-approved laboratories.
Product Testing:
- Conduct mandatory product testing in notified government-approved labs to ensure compliance with essential principles.
- See the list of CDSCO-approved testing laboratories.
Document Preparation:
- Compile comprehensive documentation including Device Master File (DMF), Plant Master File (PMF), risk management files, and quality system documents.
- Our in-depth guides on creating a Device Master File and Plant Master File can streamline this process.
Application Submission (Form MD3):
- Submit the manufacturing license application through the CDSCO MD Online Portal.
Audit by Notified Body:
- After submission, an audit is conducted by one of the CDSCO's notified bodies.
- Refer to the current list of notified bodies for audit selection.
Query Resolution:
- Address any observations or queries raised by the notified body or CDSCO authorities promptly.
License Grant (Form MD5):
- Upon satisfactory compliance, the State Licensing Authority grants the MD5 license.
Essential Documents Required for MD5 License Application
- Company Constitution (MOA/AOA)
- Proof of Ownership or Lease Agreement of Manufacturing Premises
- Details and Qualification of Technical Staff
- Fire NOC and Pollution Control Board NOC
- Device Master File (DMF) covering design, manufacturing processes, and specifications
- Plant Master File (PMF) describing the manufacturing facility and quality controls
- Essential Principles Checklist confirming compliance with CDSCO regulations
- Risk Management File highlighting hazard identification and mitigation strategies
- Test Reports from CDSCO-approved laboratories
- Product labels and Instructions for Use (IFU)
- Quality Management System (QMS) documentation aligned with ISO 13485 standards
Import Licensing Process (MD15) for Laryngectomy Tubes
For importers, the MD15 license is mandatory and is issued by the Central Licensing Authority. The process typically spans 5 to 6 months and involves:
- Preparation of detailed documentation including Manufacturing License, Free Sale Certificate, ISO 13485:2016 certificate, CE Certificate, DMF, PMF, and Wholesale License.
- Application submission on the CDSCO MD Online Portal.
- Response to departmental queries.
- License issuance on Form MD15.
Our Import License guide offers a comprehensive roadmap for importers.
Typical Timeline and Processing Duration
Stage | Duration |
---|---|
Test License (MD13) | 1.5 – 2 months |
Product Testing | 1 – 1.5 months |
Document Preparation | 2 – 3 weeks |
Application Review & Audit | 1 – 1.5 months |
Query Resolution | 2 – 4 weeks |
Total Time for MD5 | 3 – 4 months |
Government Fees and Cost Breakdown
- Application Fee: ₹5,000 per application
- Product Fee: ₹500 per product
These fees are payable during application submission through the CDSCO portal. It's important to budget additional costs for notified body audits, laboratory testing fees, and consultancy if required.
Common Challenges and Practical Solutions
- Delayed Testing Reports: Scheduling testing early and selecting notified labs with shorter turnaround times can avoid bottlenecks.
- Incomplete Documentation: Utilizing our checklists for Device and Plant Master Files ensures thorough preparation.
- Audit Non-Compliance: Pre-audit readiness assessments and mock audits can significantly mitigate risks.
- Query Backlogs: Assigning dedicated personnel to promptly address CDSCO queries expedites the process.
Expert Consultation and Support
Leveraging over two decades of regulatory expertise, we provide end-to-end support including:
- Gap analysis and readiness assessment
- Documentation drafting and review
- Coordination with notified bodies and testing labs
- Application filing and follow-up
Our clients have successfully navigated the complexities of CDSCO licensing with our hands-on approach and practical insights.
Getting Started with Your CDSCO License Application for Laryngectomy Tubes
- Initial Assessment: Evaluate your current manufacturing setup and documentation status.
- Engage a Regulatory Consultant: Consider expert guidance to streamline the process.
- Register on the CDSCO MD Online Portal: Create your account to access application forms and submissions.
- Prepare Test License Application (MD13): Begin with the test license to initiate product testing.
- Schedule Laboratory Testing: Partner with CDSCO-approved testing laboratories early.
- Compile Required Documents: Use our detailed guides to prepare your Device and Plant Master Files.
- Submit Manufacturing License Application (MD5): After successful testing and documentation.
By following these actionable steps and leveraging our expertise, manufacturers and importers of Laryngectomy Tubes can confidently enter the Indian market while ensuring compliance and patient safety.
For personalized assistance and detailed support, reach out to our regulatory team today and take the first step towards successful CDSCO licensing.
This content is brought to you by industry-leading regulatory consultants specializing in CDSCO medical device licensing, dedicated to helping manufacturers navigate India's regulatory landscape efficiently.