CDSCO License for Blanket/pad infant phototherapy unit tester
Medical Device Information
Intended Use
A portable device intended to be used in conjunction with a light meter to test a blanket/pad infant phototherapy unit. The phototherapy unit is typically positioned over specific areas of the test device at set distances to provide a measurement of light, such as average light output. It typically consists of a plastic stencil-like shape designed so the radiometer may fit at a number of positions. It is intended to be used by a healthcare professional in a clinical setting.

Comprehensive Guide to CDSCO Licensing for Blanket/Pad Infant Phototherapy Unit Tester (Class B Medical Device)
Introduction: Understanding the Blanket/Pad Infant Phototherapy Unit Tester and Its Regulatory Importance
The Blanket/Pad Infant Phototherapy Unit Tester is a specialized portable device designed to assist healthcare professionals in pediatrics and neonatology settings. It functions alongside a light meter to measure the light output of infant phototherapy units, ensuring these critical therapeutic devices deliver the appropriate light intensity to treat neonatal jaundice effectively.
Given its direct impact on neonatal care, regulatory approval from the Central Drugs Standard Control Organization (CDSCO) is crucial before manufacturing or importing this device in India. Compliance with CDSCO regulations not only ensures device safety and efficacy but also facilitates smooth market access and trust among healthcare providers.
CDSCO Regulatory Framework for Blanket/Pad Infant Phototherapy Unit Tester
As a Class B medical device, the Blanket/Pad Infant Phototherapy Unit Tester falls under moderate risk category as per CDSCO classification. The regulatory framework mandates obtaining an MD5 manufacturing license from the State Licensing Authority for domestic manufacturers. Importers must secure an MD15 import license from the Central Licensing Authority.
The regulatory process is governed by the Medical Device Rules, 2017, which emphasize quality management systems, device testing, and rigorous documentation to uphold patient safety standards.
Risk Classification and License Requirements
- Risk Class: B (Moderate risk)
- License Type for Manufacturing: MD5 License (Application Form MD3)
- Issuing Authority: State Licensing Authority
- Total Processing Time: Approximately 3-4 months
- Test License Required: Yes, MD13 Test License (1.5-2 months)
For more on device classification, manufacturers can refer to the Medical Device Classification guide.
Manufacturing License Process (MD5) for Class B Devices
- Apply for Test License (Form MD13): Begin with obtaining a test license, which permits sample testing of the device. This stage typically takes 1.5 to 2 months.
- Product Testing: Conduct mandatory device testing at CDSCO-approved laboratories to verify compliance with safety and performance standards. You can locate accredited labs on the Testing Laboratories list.
- Prepare Documentation: Compile all required documents including Device Master File, Plant Master File, Quality Management System (QMS) documents, risk management files, and test reports.
- Application Submission: Submit the manufacturing license application (Form MD3) via the CDSCO MD Online Portal.
- Audit by Notified Body: The State Licensing Authority will coordinate an audit by a notified body to verify compliance. Find your list of notified bodies here.
- Query Resolution: Address any queries or deficiencies raised during the audit or by the licensing authority promptly.
- Grant of MD5 License: Upon successful compliance, the MD5 manufacturing license will be issued on Form MD5.
For detailed guidance, see our dedicated MD5 License guide.
Manufacturing License Documents Required for Blanket/Pad Infant Phototherapy Unit Tester
- Company constitution and registration documents
- Proof of ownership or legal occupancy of manufacturing premises
- Qualification certificates and details of technical staff
- Fire No Objection Certificate (NOC) and Pollution NOC
- Device Master File outlining device specifications and design (refer to our Device Master File guide)
- Plant Master File describing manufacturing facilities and processes (see our Plant Master File guide)
- Essential Principles Checklist ensuring compliance with regulatory standards
- Risk Management File demonstrating hazard analysis and mitigation strategies (learn more about Risk Management)
- Test Reports from CDSCO-approved laboratories
- Device labels and Instructions for Use (IFU)
- Quality Management System (QMS) documentation, including ISO 13485 certification
Import License Process (MD15) for Blanket/Pad Infant Phototherapy Unit Tester
For importers, the process differs as follows:
- Document Preparation: Assemble all required import license documentation.
- Application Submission: File Form MD14 via the CDSCO MD Online Portal.
- Query Resolution: Respond to queries raised by the Central Licensing Authority.
- Grant of Import License: Receive MD15 license upon successful review.
Unlike manufacturing, no test license is required. Processing time is approximately 5-6 months.
Import License Documents Required
- Valid manufacturing license from the country of origin
- Free Sale Certificate confirming market authorization abroad
- ISO 13485:2016 Quality Management certification
- CE Certificate or equivalent international certification
- Device Master File and Plant Master File
- Wholesale license for distribution
- Company constitution and registration documents
Refer to our comprehensive Import License guide for further assistance.
Timeline and Processing Duration
Process Stage | Approximate Duration |
---|---|
Test License (MD13) | 1.5 – 2 months |
Product Testing | 1 – 1.5 months |
Document Preparation | 1 month |
License Application & Audit | 1 – 1.5 months |
Total Time for MD5 License | 3 – 4 months |
Import license processing typically takes 5-6 months.
Government Fees and Costs
MD5 Manufacturing License:
- Application Fee: Rs. 5,000
- Per Product Fee: Rs. 500
MD15 Import License:
- Class B Devices: Rs. 2,000 per site + Rs. 1,000 per product
These fees are payable through the CDSCO portal at the time of application submission.
Common Challenges and Solutions
Challenge 1: Delays in obtaining test reports from approved laboratories
- Solution: Pre-book testing slots and maintain constant communication with labs listed in the CDSCO Testing Laboratories directory.
Challenge 2: Documentation gaps leading to audit non-compliance
- Solution: Utilize templates and checklists from experienced consultants to prepare comprehensive Device and Plant Master Files.
Challenge 3: Query resolution delays
- Solution: Assign a dedicated regulatory affairs professional to monitor and respond to CDSCO queries promptly.
Challenge 4: Confusion over applicable fees and classification
- Solution: Confirm device classification early and budget accordingly. Refer to the Medical Device Classification guide for clarity.
Expert Consultation and Support
With over 25 years of regulatory expertise and having assisted 500+ medical device companies, we offer tailored support through each step of the CDSCO licensing journey. From document preparation to audit readiness and post-approval compliance, our services ensure your Blanket/Pad Infant Phototherapy Unit Tester meets all CDSCO requirements efficiently.
Getting Started with Your CDSCO License Application
- Confirm Device Classification: Verify your device’s risk class as Class B.
- Register on CDSCO MD Online Portal: Create an account at the CDSCO MD Online Portal to initiate your application.
- Prepare Test License Application: Begin with submitting Form MD13 for the test license.
- Engage with Testing Laboratories: Schedule product testing at CDSCO-approved labs.
- Assemble Required Documentation: Use our guides to prepare Device and Plant Master Files, Risk Management files, and QMS documents.
- Submit Manufacturing License Application: Once testing and documentation are complete, file Form MD3 for the MD5 license.
- Prepare for Audit: Coordinate with the notified body for the audit process.
- Address Queries Promptly: Maintain open communication with CDSCO to resolve any issues swiftly.
Taking these practical steps will set your manufacturing or importing operations on the path to successful CDSCO licensing for your Blanket/Pad Infant Phototherapy Unit Tester, enabling you to serve critical neonatal care markets in India with confidence and compliance.