CDSCO License for Blue light radiometer
Medical Device Information
Intended Use
An instrument designed to measure the radiant flux (radiant power) in the spectral range of 400 to 500 nm (i.e., blue) during bilirubinemia treatment for newborns and infants. It typically includes a pre-filter intended to remove wavelengths of light not in the 400-500 nm range (e.g., infrared light); a primary detector consisting of a temperature-stabilized, solid-state [e.g., selenium (Se) or indium-gallium-arsenide] device used to detect radiation; electronic circuits including an amplifier and a electric meter; a power source (e.g., a battery); and a display showing the results either in analogue or digital format.

Comprehensive CDSCO Licensing Guide for Blue Light Radiometer (Class B Medical Device)
Introduction: Understanding the Blue Light Radiometer and Its Regulatory Importance
The Blue Light Radiometer is an essential medical device in pediatrics and neonatology, specifically designed to measure radiant flux in the 400 to 500 nm spectral range during bilirubinemia treatment for newborns and infants. Accurate measurement of blue light intensity ensures the efficacy and safety of phototherapy, making regulatory compliance critical.
Given its classification as a Class B medical device under the Central Drugs Standard Control Organization (CDSCO) framework, obtaining the appropriate manufacturing license (MD5) is mandatory before marketing or manufacturing this device in India. Compliance with CDSCO regulations not only guarantees market access but also ensures patient safety and product reliability.
CDSCO Regulatory Framework for Blue Light Radiometer
As per the CDSCO regulations, the Blue Light Radiometer falls under Class B devices, which are moderate risk and require a state-level manufacturing license (MD5). The regulatory framework mandates manufacturers to undergo a structured process including test licensing, product testing, documentation, and audit before license grant.
Our 25+ years of experience and successful guidance to over 500 companies underscores the importance of a well-prepared application and proactive regulatory strategy.
Risk Classification and License Requirements for Blue Light Radiometer
- Risk Class: B (Moderate risk)
- License Required: MD5 License (Application Form MD3)
- Licensing Authority: State Licensing Authority
- Regulatory Timeline: Approximately 3-4 months (including test license and audit)
Since this device is Class B, the MD5 license pathway applies, involving submission of a test license (MD13), product testing in CDSCO-approved labs, document submission, and audit by a notified body.
Manufacturing License Process for Blue Light Radiometer (MD5 License)
Apply for Test License (Form MD13): This initial step grants permission to manufacture the device for testing purposes. The test license process takes around 1.5 to 2 months.
Product Testing: Submit samples to CDSCO-recognized laboratories for performance and safety testing. Refer to the CDSCO list of testing laboratories for authorized facilities.
Document Preparation: Compile all necessary documents including Device Master File, Plant Master File, Risk Management File, and Quality Management System documents.
Application Submission (Form MD3): File the manufacturing license application through the CDSCO MD Online Portal.
Audit by Notified Body: Engage with a notified body for an on-site audit. Find the suitable auditor from the list of notified bodies.
Query Resolution: Address any clarifications or corrective actions requested by the CDSCO or notified body.
License Grant (Form MD5): Upon satisfactory review, the manufacturing license is issued.
Manufacturing License Documents Required for Blue Light Radiometer
- Company Constitution and Incorporation Certificates
- Proof of Ownership or Lease of Manufacturing Premises
- Details and Qualifications of Technical Staff
- Fire NOC and Pollution Control NOC
- Device Master File (DMF) detailing design, specifications, and manufacturing process (Learn more about DMF)
- Plant Master File documenting manufacturing facilities and equipment (Plant Master File Guide)
- Essential Principles Checklist ensuring compliance with regulatory standards
- Risk Management File demonstrating hazard identification and mitigation (Risk Management Guide)
- Product Test Reports from CDSCO-approved labs
- Sample Labels and Instructions for Use (IFU)
- Quality Management System (QMS) Documents, preferably ISO 13485 compliant
Import License Process for Blue Light Radiometer (MD15 License)
For companies planning to import the Blue Light Radiometer into India, an Import License (MD15) from the Central Licensing Authority is required. This process typically takes 5-6 months.
Steps include:
- Document preparation including Manufacturing License from the country of origin, Free Sale Certificate, ISO 13485:2016 certification, CE marking (if applicable), Device and Plant Master Files, and Wholesale License.
- Submission of application through the CDSCO MD Online Portal.
- Resolution of any queries raised by CDSCO.
- Grant of Import License (Form MD15).
Import License Documents Required
- Valid Manufacturing License of the device from the exporting country
- Free Sale Certificate
- ISO 13485:2016 Certification
- CE Certificate (if applicable)
- Device Master File
- Plant Master File
- Wholesale License in India
- Company Constitution and Incorporation Documents
Timeline and Processing Duration
Process Step | Duration |
---|---|
Test License (MD13) | 1.5 - 2 months |
Product Testing | 1 - 1.5 months |
Document Preparation | 2 - 3 weeks |
Application Processing (MD5) | 1 - 2 months |
Audit by Notified Body | Scheduled within application processing |
Total Duration (Manufacturing License) | Approximately 3 - 4 months |
For import licenses (MD15), expect 5-6 months due to centralized processing.
Government Fees and Costs
- MD5 License (Class B):
- Application Fee: Rs. 5,000
- Per Product Fee: Rs. 500
Additional costs include testing fees at government-approved labs (varies by lab and tests required) and notified body audit charges (which typically range between Rs. 50,000 to Rs. 1,00,000 depending on audit scope).
Common Challenges and Solutions
Challenge 1: Delays in Product Testing
- Solution: Pre-plan testing timelines by selecting CDSCO-approved labs in advance and ensure samples meet all submission criteria.
Challenge 2: Incomplete Documentation
- Solution: Utilize comprehensive document checklists and seek expert review to ensure all files including Device Master File and Risk Management File meet CDSCO standards.
Challenge 3: Audit Non-Compliance
- Solution: Conduct internal audits and pre-audit readiness assessments to identify gaps before the notified body visit.
Challenge 4: Query Resolution Delays
- Solution: Assign a dedicated regulatory expert to respond promptly and accurately to all CDSCO queries.
Expert Consultation and Support
With over 25 years of experience facilitating CDSCO approvals for 500+ clients, we offer tailored regulatory consulting, document preparation, audit support, and liaison services. Our expertise ensures smooth navigation through complex regulatory pathways, reducing time-to-market and compliance risks.
Getting Started with Your CDSCO License Application for Blue Light Radiometer
Evaluate Device Classification: Confirm the Class B status for your Blue Light Radiometer.
Register on CDSCO MD Online Portal: Begin your application by registering your company on the CDSCO MD Online Portal.
Prepare and Submit Test License Application (MD13): Secure the test license to manufacture samples for product testing.
Coordinate Product Testing: Engage a government-approved testing laboratory early and submit samples.
Compile Complete Documentation: Gather all required files including Device Master File, Plant Master File, QMS documents, and Risk Management File.
Apply for MD5 License (Form MD3): Submit your manufacturing license application online.
Schedule and Prepare for Audit: Work with notified bodies from the official CDSCO list to complete the audit successfully.
Respond to Queries Promptly: Maintain open communication with CDSCO and address any observations without delay.
By following these actionable steps, manufacturers and importers can streamline the regulatory approval process and confidently bring the Blue Light Radiometer to the Indian healthcare market.
For detailed guidance, consult our MD5 License Guide and reach out to our expert team for personalized support.