CDSCO License for Central Nervous System Shunt including Neurological catheters and other Components
Medical Device Information
Intended Use
It is a device or combination of devices used to divert fluid from the brain or other part of the central nervous system to an internal delivery site or an external receptacle for the purpose of relieving elevated intracranial pressure or fluid volume.

Comprehensive CDSCO Licensing Guide for Central Nervous System Shunts (Class D Medical Device)
Central Nervous System (CNS) Shunts, including neurological catheters and their components, serve a critical medical function by diverting cerebrospinal fluid to relieve elevated intracranial pressure. As Class D medical devices under Indian regulations, these high-risk catheters demand rigorous compliance with the Central Drugs Standard Control Organization (CDSCO) framework to ensure safety, efficacy, and market access.
With over 25 years of experience supporting 500+ medical device manufacturers and importers, we provide a detailed roadmap for obtaining your CDSCO license for CNS Shunts. This guide covers everything from regulatory classification to application timelines, costs, and practical tips to navigate common challenges.
CDSCO Regulatory Framework for Central Nervous System Shunts
Classified as Class D due to their critical risk profile, CNS Shunts fall under stringent regulatory oversight as per CDSCO's notification 29/Misc/3/2017-DC (292) dated 06.06.2018. These devices must comply with the Medical Device Rules 2017 and follow the centralized licensing process governed by the CDSCO Central Licensing Authority.
Being implantable devices with life-sustaining functions, CNS Shunts require an MD9 manufacturing license, which entails comprehensive product testing, document verification, and audit by CDSCO officials.
Risk Classification and License Requirements
- Risk Class: D (Highest risk)
- License Type: MD9 Manufacturing License (Form MD7)
- Authority: CDSCO Central Licensing Authority
- Process Includes: Test license (MD13), product testing at government approved labs, audit, and final license grant
For detailed classification insights, manufacturers can refer to our Medical Device Classification guide.
Manufacturing License Process (MD9) for CNS Shunts
- Apply for Test License (Form MD13): Initial step to obtain permission to manufacture the device for testing purposes. This step takes approximately 1.5 to 2 months.
- Product Testing: Conduct mandatory testing at CDSCO-recognized government labs. Refer to the official list of Testing Laboratories for selection.
- Document Preparation: Compile and submit comprehensive documentation including Device Master File (DMF), Plant Master File (PMF), risk management files, labels, instructions for use (IFU), and quality management system evidence.
- Submit MD9 Application (Form MD7): File the manufacturing license application via the CDSCO MD Online Portal.
- Audit & Inspection: CDSCO inspectors conduct a thorough audit of manufacturing premises and quality systems.
- Queries & Clarifications: Address any observations or deficiencies raised.
- License Grant: Upon satisfactory compliance, the MD9 license is issued.
Our in-depth MD9 License Guide explains each step with expert tips.
Manufacturing License Documents Required for Class D CNS Shunts
- Company constitution and incorporation certificates
- Proof of ownership or lease of manufacturing premises
- Details of technical and qualified personnel
- Fire and pollution NOCs
- Device Master File (DMF) detailing design, materials, and manufacturing processes (Device Master File Guide)
- Plant Master File (PMF) documenting facility layout, equipment, and processes (Plant Master File Guide)
- Essential Principles Checklist demonstrating compliance with Indian regulations
- Risk Management File as per ISO 14971 standards (Risk Management Guide)
- Test Reports from CDSCO-approved labs
- Device labels and Instructions for Use (IFU)
- Quality Management System (QMS) documentation, preferably ISO 13485:2016 certification
Accuracy and completeness in documentation significantly reduce review times and audit queries.
Import License Process (MD15) for CNS Shunts
If your company plans to import CNS Shunts into India, an Import License under Form MD15 is mandatory.
- Authority: CDSCO Central Licensing Authority
- Application Form: MD14
- Process Duration: Approximately 5-6 months
- Documents Required: Manufacturing license from country of origin, Free Sale Certificate, ISO 13485:2016 and CE certificates, Device and Plant Master Files, wholesale license, company constitution
The import license application is also submitted via the CDSCO MD Online Portal. Our Import License Guide provides comprehensive insights.
Timeline and Processing Duration for MD9 License
- Test License (MD13): 1.5 to 2 months
- Product Testing: 1 to 1.5 months depending on lab capacity
- Application Review & Audit: 1.5 to 2 months
- Total Estimated Time: Approximately 4 to 5 months from start to finish
Planning for timelines is crucial to avoid market entry delays.
Government Fees and Costs Associated with MD9 License
- Application fee: Rs. 50,000 per application
- Product fee: Rs. 1,000 per product
- Additional costs include testing fees at government labs, audit fees charged by notified bodies (if applicable), and consultancy fees if engaging experts.
Budgeting for these expenses upfront will streamline the process.
Common Challenges and Solutions
- Incomplete Documentation: Ensure all required files such as DMF, PMF, and risk management files are up-to-date and compliant.
- Delayed Product Testing: Early engagement with government testing labs and timely submission of samples prevent bottlenecks.
- Audit Non-Compliance: Conduct thorough internal audits and pre-assessment using checklists before CDSCO inspection.
- Query Resolution Delays: Assign dedicated personnel to address CDSCO queries promptly.
Taking a proactive approach mitigates these common pain points effectively.
Expert Consultation and Support
Navigating CDSCO licensing for Class D devices like CNS Shunts requires specialized knowledge. With our extensive track record of assisting over 500 companies, we provide tailored solutions—from documentation preparation to audit support—to ensure a smooth approval journey.
Our team stays updated on regulatory changes and can liaise with CDSCO authorities, reducing your administrative burden.
Getting Started with Your CDSCO License Application
- Assess Your Device Classification: Confirm your device as Class D and review notifications specific to CNS Shunts.
- Register on the CDSCO MD Online Portal: Create your account on CDSCO MD Online Portal to initiate applications.
- Prepare Test License Application (Form MD13): Compile necessary documents and submit early.
- Schedule Product Testing: Coordinate with notified government labs.
- Develop Complete Documentation: Utilize our Device Master File and Plant Master File guides to prepare robust files.
- Apply for MD9 Manufacturing License (Form MD7): Submit via the portal and track application status.
- Prepare for CDSCO Audit: Conduct internal mock audits.
- Resolve Queries Promptly: Maintain communication with CDSCO officials.
Starting early and adhering to these action points will position your CNS Shunt device for timely CDSCO approval and successful market entry.
For personalized assistance and step-by-step support, contact us to leverage our 25+ years of regulatory expertise.