Logo
Chat on WhatsApp

CDSCO License for Contact lens radius gauge

Medical Device Information

Important Notice for Class A Devices

Class A Non-sterile Non Measuring devices are exempt from MD5 and MD15 licenses. Only CDSCO registration is required as per GSR 777(E).

Device Class
Class A

Intended Use

A measuring instrument used in  ophthalmology to determine the radius of curvature of contact lenses.

Manufacturing License
MD5
Import License
MD15
CDSCO License for Contact lens radius gauge

Introduction to Contact Lens Radius Gauge and Regulatory Importance

A Contact Lens Radius Gauge is a specialized ophthalmic measuring instrument used to determine the radius of curvature of contact lenses. This device plays a critical role in ensuring proper lens fit and patient comfort, making its accuracy and safety paramount. Given its medical application and direct impact on eye health, stringent regulatory compliance is essential before entering the Indian market.

At our firm, with over 25 years of expertise and having helped 500+ manufacturers and importers navigate CDSCO licensing, we understand the nuances involved in securing timely approvals for Class A medical devices such as Contact Lens Radius Gauges.

CDSCO Regulatory Framework for Contact Lens Radius Gauge

The Central Drugs Standard Control Organization (CDSCO) regulates all medical devices in India under the Medical Device Rules, 2017. The Contact Lens Radius Gauge falls under Class A (low risk) devices as per the notified list under Fts No. 29/MiscJO3/2020-DC (187), dated 9.8.2021. This classification determines the licensing pathway and associated requirements.

Manufacturers aiming to produce this device within India must obtain the MD5 manufacturing license from the State Licensing Authority, while importers require the MD15 import license from the Central Licensing Authority.

Risk Classification and License Requirements for Contact Lens Radius Gauge

  • Risk Class: A (Low Risk)
  • License Type: MD5 Manufacturing License (Form MD3)
  • Regulatory Authority: State Licensing Authority
  • Applicable Rules: Medical Device Rules, 2017

Class A devices like the Contact Lens Radius Gauge have a relatively straightforward licensing process compared to higher-risk devices but still require rigorous documentation, testing, and compliance audits.

Manufacturing License Process (MD5) for Contact Lens Radius Gauge

The MD5 license process involves several sequential steps:

  1. Test License Application (Form MD13): Before manufacturing, a test license must be obtained, enabling you to produce limited batches for testing.
  2. Product Testing: Samples must be tested at government-approved laboratories to verify compliance with safety and performance standards.
  3. Documentation Preparation: Compile comprehensive documents including Device Master File, Plant Master File, Risk Management File, and others.
  4. License Application (Form MD3): Submit the formal application for the MD5 license through the CDSCO MD Online Portal.
  5. Audit by Notified Body: Engage a notified body for an onsite audit of your manufacturing facility and quality systems. Refer to the list of notified bodies for approved auditors.
  6. Query Resolution: Address any technical or procedural queries raised by the licensing authority or notified body promptly.
  7. Grant of License (Form MD5): Upon satisfactory completion, the State Licensing Authority grants the manufacturing license.

This process typically takes 3-4 months, with the test license phase consuming about 1.5-2 months.

Manufacturing License Documents Required for Contact Lens Radius Gauge

To ensure a smooth application, prepare the following key documents:

  • Company Constitution Documents: Incorporation certificate, Memorandum & Articles of Association.
  • Proof of Premises Ownership or Lease Agreement: Verified address proof of manufacturing site.
  • Technical Staff Documents: Qualification and experience details of personnel responsible for manufacturing.
  • No Objection Certificates: Fire NOC, Pollution Control Board NOC.
  • Device Master File (DMF): Detailed design, material specifications, and manufacturing processes. Our comprehensive Device Master File guide provides valuable insights.
  • Plant Master File (PMF): Documentation of facility layout, equipment, and manufacturing environment. See our Plant Master File guide for best practices.
  • Essential Principles Checklist: Demonstrating compliance with Indian regulatory standards.
  • Risk Management File: Assessment and mitigation strategies tailored for the Contact Lens Radius Gauge. Learn more about medical device risk management.
  • Test Reports: From government-approved testing laboratories. Refer to the list of testing laboratories.
  • Labels and Instructions for Use (IFU): Clear product labeling and user manuals.
  • Quality Management System (QMS) Documents: ISO 13485:2016 certification and related SOPs.

Import License Process (MD15) for Contact Lens Radius Gauge

For importers, the process is managed by the Central Licensing Authority and involves:

  • Preparing comprehensive documentation including existing manufacturing license, Free Sale Certificate, ISO 13485:2016, and CE Certificate.
  • Submitting the application via the CDSCO MD Online Portal on Form MD14.
  • Responding to any queries raised during the review.
  • License grant on Form MD15.

The import license process generally takes 5-6 months.

Import License Documents Required

  • Valid Manufacturing License (MD5 or MD9) from the country of origin.
  • Free Sale Certificate issued by the regulatory authority of the exporting country.
  • ISO 13485:2016 certification.
  • CE Certificate or equivalent.
  • Device Master File and Plant Master File.
  • Wholesale license (if applicable).
  • Company Constitution Documents.

Timeline and Processing Duration

Process StepDuration
Test License (MD13)1.5 to 2 months
Product Testing3 to 4 weeks
Document Preparation2 to 4 weeks
MD5 License ApplicationSubmitted online
Audit by Notified BodyScheduled within 4 weeks
Query Resolution2 to 3 weeks
License GrantTotal 3 to 4 months

For import licenses (MD15), expect 5-6 months from application to grant.

Government Fees and Costs

For the Contact Lens Radius Gauge (Class A device), the fee structure is as follows:

  • MD5 License: Rs 5,000 per application + Rs 500 per product.
  • Test License (MD13): Included in the overall process.
  • Import License (MD15): Approximately 1,000persite+1,000 per site + 50 per product.

Additional costs include testing fees at approved labs and notified body audit charges, which vary by agency.

Common Challenges and Solutions

  • Delayed Test Reports: Selecting accredited and responsive testing laboratories is crucial. Plan sample dispatch early.
  • Incomplete Documentation: Use detailed checklists and professional templates. Our guides and consulting services can help.
  • Audit Non-compliance: Ensure QMS aligns with ISO 13485:2016 and conduct internal audits before official inspections.
  • Query Handling Delays: Assign dedicated regulatory personnel or consultants to respond swiftly.

Expert Consultation and Support

Navigating the CDSCO licensing process for specialized ophthalmic devices like the Contact Lens Radius Gauge requires expert knowledge. We offer end-to-end support from document preparation, audit readiness, to application submission through the CDSCO MD Online Portal.

Our extensive experience with over 500 successful client cases ensures you avoid common pitfalls and expedite your market entry.

Getting Started with Your CDSCO License Application

  1. Classify Your Device Accurately: Confirm your device’s risk class using the Medical Device Classification resource.
  2. Initiate Test License Application: Apply for the MD13 test license immediately to begin prototype manufacturing.
  3. Select Accredited Testing Laboratory: Coordinate sample testing through government-approved labs.
  4. Prepare Comprehensive Documentation: Leverage our Device and Plant Master File guides to ensure completeness.
  5. Schedule Notified Body Audit: Choose a notified body from the official list early to avoid delays.
  6. Submit Your License Application: Use the CDSCO MD Online Portal for all submissions.

For manufacturers and importers committed to compliance and timely approvals, partnering with seasoned regulatory consultants can be a game-changer. Contact us to discuss your project and start your licensing journey today.

Get Expert Help

Free consultation for your medical device license

24/7 Support Available

Why Choose Us

500+ Licenses Obtained
100% Success Rate
15+ Years Experience
24/7 Support Available

About the Author

avatar
Tails Azimuth
@Twitter