CDSCO License for Rectosocope/proctoscope handle end-cap
Medical Device Information
Important Notice for Class A Devices
Class A Non-sterile Non Measuring devices are exempt from MD5 and MD15 licenses. Only CDSCO registration is required as per GSR 777(E).
Intended Use
A small cap intended to be fitted to the proximal end of the handle of a rectoscope or proctoscope during an examination procedure to provide an airtight seal so that air can be pumped through the scope to inflate the bowel.

Comprehensive Guide to CDSCO License for Rectoscope/Proctoscope Handle End-Cap (Class A)
Navigating the regulatory landscape for medical devices in India can be complex, especially for niche devices like the Rectoscope/Proctoscope handle end-cap. This small but critical accessory, intended to provide an airtight seal during gastroenterological examinations, falls under Class A risk category as per CDSCO's classification. With over 25 years of experience and having supported 500+ companies, we provide you a detailed, step-by-step guide to secure your CDSCO license seamlessly.
Understanding Your Device and Its Regulatory Importance
The Rectoscope/Proctoscope handle end-cap is designed to fit the proximal end of the handle, ensuring an airtight seal to allow bowel inflation during examination. Though a seemingly simple component, it plays a vital role in ensuring procedural efficacy and patient safety. The device is categorized under gastroenterology and notified under the CDSCO notification number 29/Misc./03/2020-DC (182) dated 27.09.2021.
Given its Class A risk classification (lowest risk), the regulatory requirements are less stringent than higher-risk devices but still demand thorough documentation and compliance verification.
CDSCO Regulatory Framework for Rectoscope/Proctoscope Handle End-Cap
The Central Drugs Standard Control Organisation (CDSCO) governs medical device approvals in India. Devices are classified into four risk classes (A to D), with Class A being low risk. For Class A devices like the Rectoscope handle end-cap, the State Licensing Authority issues the manufacturing license known as the MD5 license.
You must comply with the Medical Device Rules, 2017, which detail the licensing, manufacturing, import, and sale requirements.
Risk Classification and License Requirements
- Device: Rectoscope/Proctoscope handle end-cap
- Risk Class: A (Low risk)
- License Required: MD5 Manufacturing License (Application Form MD3)
- Licensing Authority: State Licensing Authority
- Process Duration: Approximately 3 to 4 months
Manufacturing License Process (MD5)
The MD5 license process for Class A devices involves several key steps:
Obtain Test License (Form MD13): Before manufacturing license application, you must apply for and secure a test license which enables you to manufacture for testing and evaluation. This typically takes 1.5 to 2 months.
Product Testing: Conduct product testing at CDSCO-approved laboratories to demonstrate compliance with applicable standards. Refer to the list of testing laboratories recognized by CDSCO.
Document Preparation: Compile all necessary documents including Device Master File, Plant Master File, Risk Management File, and Essential Principles Checklist.
Apply for MD5 License (Form MD3): Submit your application through the CDSCO MD Online Portal for the manufacturing license.
Audit by Notified Body: An audit will be conducted by a notified body listed on the CDSCO notified bodies list to verify compliance.
Respond to Queries: Address any queries or observations raised by the licensing authority or notified body promptly.
License Grant: Upon successful compliance and audit, the MD5 manufacturing license will be granted.
Manufacturing License Documents Required
To ensure a smooth application process, prepare the following essential documents:
- Company Constitution (Incorporation Certificate, Partnership Deed, etc.)
- Proof of Premises Ownership or Lease Agreement
- Technical Staff Qualification Certificates (Minimum one technical expert as per rule)
- Fire NOC and Pollution Control Board NOC
- Device Master File (DMF) detailing design, specifications, and manufacturing process (Device Master File Guide)
- Plant Master File (PMF) with details of manufacturing facilities (Plant Master File Guide)
- Essential Principles Checklist (demonstrating compliance with safety and performance requirements)
- Risk Management File outlining hazard identification and mitigation (Risk Management)
- Test Reports from CDSCO-approved laboratories
- Labels and Instructions for Use (IFU) samples
- Quality Management System (QMS) Documents such as ISO 13485 certification
Import License Process (MD15) for Rectoscope Handle End-Cap
If you are an importer rather than a manufacturer, you will need an MD15 import license granted by the Central Licensing Authority. The process typically takes 5 to 6 months and requires:
- Manufacturing License of the foreign manufacturer
- Free Sale Certificate
- ISO 13485:2016 and CE Certificates
- Device Master File and Plant Master File
- Wholesale License
- Company Constitution
Submit your application in Form MD14 via the CDSCO MD Online Portal. Note that unlike manufacturing licenses, a test license is not required here.
Timeline and Processing Duration
Process Step | Duration |
---|---|
Test License (MD13) | 1.5 – 2 months |
Product Testing | 2 – 3 weeks |
Document Preparation | 3 – 4 weeks |
MD5 License Application | 1 month |
Audit & Query Resolution | 3 – 4 weeks |
Total Time | 3 – 4 months approx |
Government Fees and Costs
The fees for MD5 license for Class A devices are as follows:
- Application fee: INR 5,000 per application
- Product fee: INR 500 per product
Additional costs to consider include product testing fees at approved labs and notified body audit fees, which vary by service provider.
Common Challenges and Solutions
Challenge 1: Delays in Document Preparation
Many manufacturers underestimate the time required to prepare comprehensive Device Master Files and Risk Management documentation. Early investment in documentation, using expert consultants, can drastically reduce delays.
Challenge 2: Selection of Notified Body
Choosing an inexperienced notified body may lead to prolonged audits or additional non-compliance findings. Refer to the official list of notified bodies and select those with proven expertise in gastroenterology devices.
Challenge 3: Incomplete Test Reports
Test reports must be from CDSCO-approved labs and cover all relevant parameters. Engage with labs early and verify their scope of testing for your device.
Expert Consultation and Support
Given the nuances of CDSCO licensing, partnering with consultants experienced in gastroenterology device approvals can streamline the process. We have successfully guided over 500 companies through MD5 licensing, ensuring compliance, timely documentation, and prompt audit readiness.
Our consultancy includes:
- Customized gap analysis for your technical files
- Coordination with testing laboratories and notified bodies
- Application submission and follow-up on the CDSCO portal
- Query management and audit support
Getting Started with Your CDSCO License Application
Register on the CDSCO MD Online Portal: Begin by creating your account and familiarizing yourself with the interface.
Prepare your Test License Application (Form MD13): Compile preliminary documents and submit the test license application.
Select a CDSCO-Approved Testing Laboratory: Engage a lab to plan your product testing in alignment with notified standards.
Develop Comprehensive Technical Documentation: Use our Device Master File Guide and Plant Master File Guide as templates.
Plan for Notified Body Audit: Schedule your audit with an accredited body from the list of notified bodies.
Submit Your MD5 License Application (Form MD3): After successful testing and documentation, submit your manufacturing license application.
Prepare for Queries and Inspection: Maintain readiness to promptly respond to any questions or inspection visits.
By following these clear, actionable steps and leveraging expert guidance, you can confidently enter the Indian market with your Rectoscope/Proctoscope handle end-cap.
For personalized assistance and detailed project planning, contact our regulatory consulting team today. Our proven track record ensures your CDSCO approval journey is efficient, compliant, and stress-free.