CDSCO License for Intracranial  pressure monitor device

Medical Device Information

Device Class
Class D

Intended Use

Intended for intermittent or continuous measurement and  display of intracranial pressure (ICP). It is used in conjunction with an invasive intracranial device.

Manufacturing License
MD9
Import License
MD15
CDSCO License for Intracranial  pressure monitor device

Comprehensive Guide to CDSCO Licensing for Intracranial Pressure Monitor Devices (Class D)

Intracranial pressure (ICP) monitor devices are critical neurological medical devices designed for the intermittent or continuous measurement and display of intracranial pressure. These devices, used alongside invasive intracranial equipment, play a pivotal role in managing patients with traumatic brain injuries, hydrocephalus, or other neurological disorders. Given their high-risk classification (Class D under CDSCO regulations), they require stringent regulatory oversight to ensure safety and efficacy in the Indian market.

With over 25 years of expertise and having assisted 500+ companies in navigating the CDSCO licensing landscape, we provide you with a detailed, actionable roadmap tailored specifically for intracranial pressure monitor devices.


CDSCO Regulatory Framework for Intracranial Pressure Monitor Devices

In India, the Central Drugs Standard Control Organization (CDSCO) regulates medical devices under the Medical Device Rules (MDR) 2017, amended periodically. Intracranial pressure monitor devices fall under the neurological category and are notified as a Class D device, the highest risk class due to their invasive use and critical clinical implications.

The official notification for this device is 29/Misc/03/2020-DC (201) dated 27.09.2021. This notification mandates compliance with strict regulatory requirements including detailed technical documentation, product testing, quality management systems, and audits.

Risk Classification and License Requirements

  • Risk Class: D (Highest risk)
  • Regulatory Authority: CDSCO Central Licensing Authority
  • License Type: MD9 Manufacturing License (Form MD7)
  • Import License: MD15 (Form MD14) if importing

Class D devices require a rigorous approval process involving:

  • Test license acquisition
  • Product testing at CDSCO-approved laboratories
  • Comprehensive technical dossier submission
  • On-site audit by CDSCO inspectors

For a detailed understanding of medical device classification, you can refer to our Medical Device Classification guide.

Manufacturing License Process (MD9) for Intracranial Pressure Monitor Devices

The MD9 license is mandatory for manufacturers intending to produce intracranial pressure monitor devices in India. The process encompasses several critical steps:

  1. Obtain Test License (Form MD13): First, secure a test license from CDSCO, which is valid for 3-6 months and allows you to test your product legally.

  2. Product Testing: Get your device tested at one of the CDSCO-approved testing laboratories. Testing verifies device safety, performance, and compliance with Essential Principles.

  3. Prepare Technical Documentation: Compile all required documents including Device Master File, Plant Master File, Risk Management File, and QMS documentation.

  4. Submit Application (Form MD7): Apply online via the CDSCO MD Online Portal with the complete dossier.

  5. CDSCO Audit: Expect an on-site inspection by CDSCO officials to assess manufacturing premises, quality systems, and documentation.

  6. Query Resolution: Respond promptly to any queries raised by CDSCO during the review.

  7. License Grant (Form MD9): Upon successful completion, CDSCO issues the manufacturing license.

For a comprehensive walkthrough, our MD9 License Guide offers detailed insights.

Manufacturing License Documents Required for Class D Devices

To facilitate a smooth application, ensure you have the following documentation ready:

  • Company Constitution and Registration Certificates
  • Proof of Ownership or Lease Agreement of Manufacturing Premises
  • Detailed CVs and qualifications of Technical Staff
  • Fire NOC and Pollution Control NOC
  • Device Master File (DMF) detailing design, specifications, and manufacturing processes (Device Master File Guide)
  • Plant Master File (PMF) describing the manufacturing environment and quality control (Plant Master File Guide)
  • Essential Principles Compliance Checklist
  • Risk Management File compliant with ISO 14971 (Risk Management Guide)
  • Test Reports from CDSCO-recognized labs
  • Product Labels and Instructions for Use (IFU)
  • Quality Management System Documents, preferably ISO 13485:2016 certification

Ensuring these documents are accurate and complete mitigates delays during CDSCO review.

Import License Process (MD15) for Intracranial Pressure Monitor Devices

For importers aiming to bring intracranial pressure monitor devices into India, an MD15 import license is obligatory. The central regulatory authority governs this process, which includes:

  1. Document Preparation: Collate manufacturing license of the foreign manufacturer, Free Sale Certificate, ISO 13485:2016 certification, CE certificate (if applicable), Device and Plant Master Files, wholesale license, and company constitution.

  2. Application Submission: Apply via the CDSCO MD Online Portal using Form MD14.

  3. Review and Query Resolution: Address any regulatory queries promptly.

  4. License Grant (Form MD15): Upon approval, the import license is issued, valid typically for 5 years.

Refer to our Import License Guide for detailed procedural assistance.

Import License Documents Required for Class D Devices

  • Manufacturing License of foreign manufacturer
  • Free Sale Certificate from country of origin
  • ISO 13485:2016 certification
  • CE Certificate or equivalent
  • Device Master File and Plant Master File
  • Wholesale License for Indian importer
  • Company Constitution & Registration Certificates

Timeline and Processing Duration

  • MD9 Manufacturing License: Approximately 4-5 months in total.

    • Test License (MD13): 1.5 to 2 months
    • Product Testing: 1 to 1.5 months
    • Audit and Review: 1 to 1.5 months
  • MD15 Import License: Approximately 5-6 months

Timelines can vary based on document completeness, query resolution speed, and audit scheduling.

Government Fees and Costs

  • MD9 License Application Fee: Rs. 50,000 per application + Rs. 1,000 per product
  • MD13 Test License Fee: Typically Rs. 50,000 (varies by state)
  • Audit and Testing Costs: Variable, depending on notified body and testing laboratory fees
  • MD15 Import License Fee:
    • Class D devices: USD 3,000 per site + USD 1,500 per product

Budgeting realistically for these fees ensures no surprises during the application process.

Common Challenges and Solutions

  • Incomplete Documentation: Often delays arise from missing or inadequate technical files. Solution: Use our checklists and expert review services.

  • Testing Delays: Labs can be overloaded; plan testing early and select CDSCO-approved labs from the Testing Laboratories list.

  • Audit Scheduling Conflicts: Book audits well in advance and prepare thoroughly to avoid re-inspections.

  • Regulatory Queries: Prompt, clear responses with supporting evidence expedite approvals.

  • Understanding MDR Updates: Stay informed about regulatory amendments to maintain compliance.

Expert Consultation and Support

Navigating the CDSCO licensing for a high-risk device like an intracranial pressure monitor can be complex. With our 25+ years of industry experience and over 500 successful client engagements, we offer:

  • End-to-end licensing support
  • Tailored documentation preparation
  • Pre-audit readiness assessments
  • Liaison with CDSCO authorities
  • Regulatory training for your teams

Our expertise ensures your application is robust, compliant, and ready to withstand regulatory scrutiny.

Getting Started with Your CDSCO License Application

  1. Evaluate Your Device Classification: Confirm Class D status and related requirements.

  2. Prepare Preliminary Documentation: Assemble company constitution, premises proofs, and technical staff details.

  3. Apply for Test License (MD13): Submit your application via the CDSCO MD Online Portal.

  4. Identify CDSCO-Approved Testing Laboratory: Schedule testing early to align with test license validity.

  5. Develop Device Master File and Plant Master File: Utilize expert templates and refer to our DMF and PMF guides.

  6. Implement Risk Management and QMS: Ensure compliance with ISO 14971 and ISO 13485 standards.

  7. Prepare for CDSCO Audit: Conduct internal audits and gap assessments.

  8. Submit MD9 License Application: Once testing and documentation are complete, apply on the CDSCO portal.

Starting early and leveraging expert help can reduce your approval timeline substantially and facilitate a successful market entry.

For personalized advice and hands-on support, contact us to schedule a consultation.


With rigorous preparation and expert guidance, your intracranial pressure monitor device can achieve timely CDSCO approval, unlocking access to the rapidly growing Indian neurological device market.