Logo
Chat on WhatsApp

CDSCO License for Nerve guide, non- bioabsorbable

Medical Device Information

Device Class
Class D

Intended Use

Non-bioabsorbable material intended to be used to create a tunnel through which a discontinuous peripheral nerve can regenerate to bridge the proximal and distal nerve stumps.

Manufacturing License
MD9
Import License
MD15
CDSCO License for Nerve guide, non- bioabsorbable

Comprehensive Guide to CDSCO Licensing for Nerve Guide, Non-Bioabsorbable (Class D Medical Device)

Navigating the regulatory landscape for high-risk medical devices such as non-bioabsorbable nerve guides can be complex. With over 25 years of experience assisting 500+ manufacturers and importers, we provide you with a detailed, step-by-step guide to secure your CDSCO license efficiently and compliantly.

Understanding the Device and Its Regulatory Importance

The nerve guide, non-bioabsorbable, serves a critical function in neurological repair by creating a tunnel for peripheral nerve regeneration, bridging discontinuous nerve stumps. Classified as a Class D device under India's regulatory framework due to its high-risk nature and direct impact on patient safety, it demands stringent compliance with CDSCO regulations. This ensures that all safety, efficacy, and quality standards are met before the device reaches the market.

CDSCO Regulatory Framework for Nerve Guide Devices

In India, medical devices are regulated under the Medical Device Rules (MDR) 2017, with the CDSCO acting as the central authority. For Class D devices like the nerve guide, the licensing process is centralized, requiring adherence to the highest standards of evaluation, including technical documentation, testing, and audits.

Risk Classification and License Requirements

As a Class D device, the nerve guide falls under the highest risk category, necessitating the MD9 manufacturing license issued by the Central Licensing Authority. The classification aligns with the device's critical role in patient health and the potential risks involved.

Manufacturing License Process for Class D Devices (MD9 License)

The MD9 license process is comprehensive and typically spans 4-5 months. Here's an overview:

  1. Test License Acquisition (Form MD13): Initiate with a test license application which takes about 1.5–2 months.
  2. Product Testing: Conduct mandatory product testing at CDSCO-approved laboratories. Refer to the list of testing laboratories for approved facilities.
  3. Document Preparation: Compile all necessary documentation, including Device Master File, Plant Master File, Essential Principles Checklist, and Risk Management File.
  4. License Application (Form MD7): Submit your application for the MD9 license through the CDSCO MD Online Portal.
  5. Inspection and Audit: CDSCO inspectors conduct a detailed audit of your manufacturing facility and quality systems.
  6. Query Resolution: Respond promptly to any queries raised during the review.
  7. Grant of License (Form MD9): Upon satisfactory compliance, the license is granted.

Manufacturing License Documents Required

For the nerve guide device, ensure the following documents are meticulously prepared and submitted:

  • Company Constitution and Incorporation Certificates
  • Proof of Ownership or Lease of Manufacturing Premises
  • Technical Staff Details: Qualifications and experience of personnel
  • Fire NOC and Pollution Control Board NOC
  • Device Master File (DMF): Detailed device design, manufacturing process, and specifications (Device Master File guide)
  • Plant Master File (PMF): Facility details, quality management systems, and equipment (Plant Master File guide)
  • Essential Principles Checklist: Compliance with Indian MDR Essential Principles
  • Risk Management File: Documentation of risk analysis and mitigation strategies (Risk Management guide)
  • Test Reports: From CDSCO-approved labs validating device safety and performance
  • Labels and Instructions for Use (IFU): Compliant with regulatory standards
  • Quality Management System (QMS) Documentation: ISO 13485:2016 certification and internal procedures

Import License Process (MD15) for Nerve Guides

If importing the nerve guide device into India, an Import License (Form MD14 for application, MD15 for license) from the Central Licensing Authority is mandatory. The process typically takes 5-6 months and requires:

  • Manufacturing License from the country of origin
  • Free Sale Certificate
  • ISO 13485:2016 Certification
  • CE Certificate or other relevant approvals
  • Device Master File and Plant Master File
  • Wholesale License for distribution
  • Company Constitution and Incorporation Documents

Submit your application via the CDSCO MD Online Portal. Government fees vary based on device class, with Class D devices incurring higher charges.

Timeline and Processing Duration

Process StepDuration
Test License (MD13)1.5 – 2 months
Product Testing2 – 3 weeks
Document Preparation3 – 4 weeks
Application Submission (MD7)Immediate
CDSCO Audit and Inspection4 – 6 weeks
Query Resolution and Approval3 – 4 weeks
Total Estimated Time4 – 5 months

Government Fees and Costs

  • Application Fee: ₹50,000 per application
  • Product Fee: ₹1,000 per product
  • Testing Costs: Variable, depending on the number of tests and laboratories
  • Audit Fees: Borne by the applicant, payable to the notified body or CDSCO

Common Challenges and Practical Solutions

  • Delayed Test Reports: Plan testing early and choose CDSCO-approved labs listed here to avoid bottlenecks.
  • Incomplete Documentation: Utilize our detailed checklists and guides to ensure all documents, especially the Device Master File and Risk Management File, are comprehensive.
  • Audit Non-Compliance: Conduct internal audits and pre-audit readiness assessments to ensure compliance with CDSCO and ISO 13485 standards.
  • Query Management: Respond to CDSCO queries clearly and promptly, leveraging expert consultancy to avoid delays.

Expert Consultation and Support

Given the complexity of the MD9 licensing process for Class D devices, partnering with experienced regulatory consultants can streamline approvals. We provide:

  • End-to-end application management
  • Documentation preparation and review
  • Coordination with CDSCO inspectors and notified bodies
  • Training on regulatory compliance and QMS implementation

Getting Started with Your CDSCO License Application

  1. Evaluate Your Device Classification: Confirm your nerve guide is correctly classified as Class D.
  2. Initiate Test License Application: File Form MD13 via the CDSCO MD Online Portal to start product testing.
  3. Prepare Documentation Concurrently: Begin compiling your Device Master File, Plant Master File, and Risk Management File.
  4. Engage with CDSCO-Approved Testing Labs: Schedule timely product testing to avoid process delays.
  5. Plan for Audit: Ensure your manufacturing site and QMS are inspection-ready.
  6. Submit MD9 License Application: Once testing and documentation are complete, submit Form MD7.

For a seamless journey through the regulatory maze, leverage our extensive expertise and comprehensive resources. Contact us today to discuss your nerve guide device licensing requirements and ensure your product reaches the Indian market swiftly and compliantly.

Get Expert Help

Free consultation for your medical device license

24/7 Support Available

Why Choose Us

500+ Licenses Obtained
100% Success Rate
15+ Years Experience
24/7 Support Available

About the Author

avatar
Tails Azimuth
@Twitter