CDSCO License for Rigid ureterorenoscope
Medical Device Information
Intended Use
An endoscope with a rigid or semi-rigid inserted portion intended for the visual examination and treatment of the ureter and the renal pelvis; some types may have a flexible tip at the distal end of the inserted portion.

Comprehensive Guide to CDSCO Licensing for Rigid Ureterorenoscope (Class B Medical Device)
As seasoned regulatory consultants with over 25 years of experience helping 500+ companies successfully register medical devices in India, we understand the complexities manufacturers and importers face. The rigid ureterorenoscope, a Class B device under the urology category, requires careful navigation through the CDSCO regulatory framework. In this guide, we provide detailed, actionable insights on licensing, timelines, costs, and documentation specific to this device type.
Understanding the Rigid Ureterorenoscope and Its Regulatory Importance
A rigid ureterorenoscope is an endoscopic instrument with a rigid or semi-rigid inserted portion, primarily designed for the visual examination and treatment of the ureter and renal pelvis. Some versions feature a flexible distal tip to enhance maneuverability. Given its invasive nature and critical clinical role, regulatory oversight ensures the device's safety, efficacy, and quality before market authorization.
The Central Drugs Standard Control Organization (CDSCO) governs medical device approvals in India. The rigid ureterorenoscope is classified as a Class B device (low to moderate risk), meaning the regulatory pathway involves obtaining a manufacturing license under MD5 and compliance with state authority regulations.
CDSCO Regulatory Framework for Rigid Ureterorenoscope
The rigid ureterorenoscope falls under the notified medical device category with File No. 29/Misc./03/2020-DC (145) dated 23.8.2021. Compliance with this notification is mandatory for manufacturing or marketing in India.
The CDSCO framework mandates:
- Risk classification and license requirements
- Test license acquisition
- Product testing at CDSCO-approved laboratories
- Submission of detailed technical and quality documents
- Audit by notified bodies
Manufacturers and importers must submit applications via the CDSCO MD Online Portal, ensuring all forms, fees, and documentation meet standards.
Risk Classification and License Requirements for Class B Devices
Class B devices like the rigid ureterorenoscope require an MD5 manufacturing license granted by the State Licensing Authority. The MD5 license is applied for using Form MD3 after fulfilling prerequisite steps such as obtaining a test license (Form MD13), product testing, and audits.
For importers, the MD15 import license granted by the Central Licensing Authority applies but is typically required for higher-class devices or when importing devices manufactured outside India.
Manufacturing License Process for Rigid Ureterorenoscope (MD5 License)
The pathway to obtaining an MD5 license is detailed and involves several sequential steps:
Test License Application (Form MD13): Initiate by applying for a test license, which allows the manufacture and testing of the device samples. This process generally takes 1.5 to 2 months.
Product Testing: Submit device samples to CDSCO-recognized testing laboratories. Refer to the comprehensive list of testing laboratories for accredited options. Testing typically takes 1-2 months depending on the device complexity.
Documentation Preparation: Assemble critical documentation including Device Master File (DMF), Plant Master File (PMF), Essential Principles Checklist, Risk Management File, and Quality Management System (QMS) documents. Our Device Master File guide and Plant Master File guide offer practical frameworks tailored for medical devices.
License Application Submission (Form MD3): Upload the complete application and documents via the CDSCO MD Online Portal.
Audit by Notified Body: An audit is conducted by a notified body from the CDSCO notified bodies list to verify compliance with Good Manufacturing Practices (GMP) and quality systems.
Query Resolution: Address any queries or clarifications raised by CDSCO or the notified body promptly.
Grant of Manufacturing License (Form MD5): Upon satisfactory evaluation, the MD5 license is granted.
Manufacturing License Documents Required for Rigid Ureterorenoscope
For a Class B device like the rigid ureterorenoscope, you must prepare and submit the following documents:
- Company Constitution (e.g., Memorandum and Articles of Association)
- Proof of ownership or lease agreement of manufacturing premises
- Details and qualifications of technical staff
- Fire NOC and Pollution Control Board NOC
- Device Master File (DMF) detailing design, materials, and manufacturing process
- Plant Master File (PMF) describing manufacturing facility and quality systems
- Essential Principles Checklist demonstrating compliance with Indian regulations
- Risk Management File following ISO 14971 principles
- Product Test Reports from CDSCO-approved labs
- Labels and Instructions for Use (IFU) complying with labeling regulations
- Quality Management System Documents, e.g., ISO 13485:2016 certification
Import License Process for Rigid Ureterorenoscope (MD15 License)
While primarily relevant for manufacturers, importers of rigid ureterorenoscope devices must apply for an MD15 import license through the Central Licensing Authority. The process includes:
Document Preparation: Collect essential documents such as manufacturing license from the country of origin, Free Sale Certificate, ISO 13485:2016 certification, CE certificate, and DMF/PMF.
Application Submission (Form MD14): File the import license application via the CDSCO MD Online Portal.
Query Resolution: Respond to CDSCO queries within stipulated timelines.
Grant of Import License (Form MD15): Upon clearance, the import license is issued.
Import License Documents Required
- Valid Manufacturing License from exporting country
- Free Sale Certificate
- ISO 13485:2016 Certificate
- CE Certificate (if applicable)
- Device Master File and Plant Master File
- Wholesale License (if applicable)
- Company Constitution
Timeline and Processing Duration
License Type | Process Duration | Key Steps | Fees (INR) |
---|---|---|---|
Test License (Form MD13) | 1.5-2 months | Sample Testing | Included in MD5 fees |
MD5 Manufacturing License (Form MD3) | 3-4 months (including test license) | Document submission, audit, query resolution | ₹5,000 + ₹500 per product |
MD15 Import License (Form MD14) | 5-6 months | Document review, query resolution | Varies by class; Class B approx ₹2,000 + ₹1,000 per product |
For rigid ureterorenoscopes (Class B), expect a total of approximately 3 to 4 months from test license application to MD5 license grant.
Government Fees and Costs
- MD5 License Application: ₹5,000 per application plus ₹500 per product
- MD15 Import License: For Class B devices, ₹2,000 per site and ₹1,000 per product
Additional costs include testing fees charged by laboratories and fees related to notified body audits.
Common Challenges and Solutions in Obtaining CDSCO License for Rigid Ureterorenoscope
Challenge: Incomplete or poorly organized documentation resulting in delays.
- Solution: Utilize structured templates for DMF, PMF, and risk management files. Our guides help streamline documentation.
Challenge: Delays in product testing due to sample issues or lab backlog.
- Solution: Early engagement with CDSCO-approved labs and pre-submission sample validation.
Challenge: Non-compliance with notified body audit findings.
- Solution: Conduct internal audits and pre-assessment before official audits.
Challenge: Misunderstanding application portal requirements.
- Solution: Follow stepwise instructions on the CDSCO MD Online Portal and seek expert consultation.
Expert Consultation and Support
Navigating CDSCO licensing requires in-depth regulatory knowledge and practical experience. Our seasoned consultants provide:
- Detailed gap analysis and regulatory strategy specific to rigid ureterorenoscopes
- Document preparation and review
- Liaison with CDSCO officials and notified bodies
- Support in audit readiness and query resolution
Partnering with experts minimizes delays, reduces risks, and accelerates market entry.
Getting Started with Your CDSCO License Application for Rigid Ureterorenoscope
Initiate a Regulatory Assessment: Confirm your device classification and confirm applicability of MD5 license.
Prepare Test License Application: Gather preliminary documents and apply for the test license (Form MD13) via the CDSCO portal.
Engage Testing Labs Early: Coordinate sample submission to avoid bottlenecks.
Compile Comprehensive Documentation: Use our Device Master File guide and Plant Master File guide to ensure completeness.
Schedule Notified Body Audit: Select a notified body from the official list and prepare for the audit.
Submit MD5 License Application: Once the test license and testing reports are ready, submit Form MD3 through the CDSCO MD Online Portal.
Respond Promptly to Queries: Maintain close communication with CDSCO to expedite approvals.
By following these practical steps and leveraging our extensive regulatory expertise, manufacturers and importers of rigid ureterorenoscopes can confidently and efficiently obtain their CDSCO licenses, ensuring compliance and successful market entry in India.