CDSCO License for Trocars
Medical Device Information
Intended Use
A trocar is made up of an obturator (which may be a metal or plastic sharpened or non-bladed tip), a cannula(basically a hollow tube), and a seal. The trocar functions as a portal for the subsequent placement of other instruments, such as graspers, scissors, staplers, etc. It is also intended to remove air or fluid for the pleural space in a closed, one way fashion.

Comprehensive Guide to Obtaining CDSCO License for Trocars (Class B Medical Device)
At our consultancy, with over 25 years of experience and having assisted 500+ companies in successfully securing CDSCO licenses, we understand the nuances involved in navigating India’s regulatory landscape for medical devices. In this guide, we focus on Trocars, a Class B medical device under the catheter category, and provide you with a step-by-step roadmap to obtain your manufacturing or import license efficiently.
Understanding Trocars and Their Regulatory Importance
A trocar is a critical surgical instrument consisting of an obturator, cannula, and seal. It serves as a portal for introducing other surgical instruments or for evacuating air or fluid from the pleural space. Given its invasive nature and involvement in critical procedures, the Indian regulator classifies trocars as Class B devices under the catheter category (Notification 29/Misc/3/2017-DC (18), dated 16.08.2018).
Proper licensing ensures compliance with safety, quality, and efficacy standards, facilitating smooth market entry and building trust with healthcare providers.
CDSCO Regulatory Framework for Trocars (Class B Catheters)
The Central Drugs Standard Control Organization (CDSCO) governs the import and manufacture of medical devices in India. The regulatory framework for Class B devices such as trocars falls under the purview of the State Licensing Authority for manufacturing licenses (MD5) and Central Licensing Authority for import licenses (MD15).
You are required to adhere to the Medical Device Rules, 2017, and relevant notifications while applying.
Risk Classification and License Requirements for Trocars
Trocars are designated as Class B devices due to moderate risk associated with their use. This classification dictates licensing requirements:
- Manufacturing License: MD5 License (Application Form MD3) issued by the State Licensing Authority.
- Import License: MD15 License (Application Form MD14) issued by the Central Licensing Authority.
Manufacturers must first obtain a Test License (Form MD13) before applying for the MD5 license. Importers skip the test license step but must prepare extensive documentation.
Manufacturing License Process (MD5) for Trocars
The MD5 license process for Class B devices typically takes 3 to 4 months and involves the following stages:
Apply for Test License (MD13): Initial application for test license to conduct product testing. This process takes around 1.5 to 2 months.
Product Testing: Testing must be conducted at CDSCO-approved laboratories. Check the list of testing laboratories for authorized centers.
Documentation Preparation: Preparation of Device Master File, Plant Master File, Essential Principles Checklist, Risk Management File, and Quality Management System (QMS) documents as per CDSCO guidelines.
Apply for MD5 License (Form MD3): Submit the manufacturing license application on the CDSCO MD Online Portal.
Audit by Notified Body: An audit by a CDSCO approved notified body is mandatory. Refer to the Notified Bodies List for MD5 Audit for authorized auditors.
Query Resolution: Respond to any queries raised by the licensing authority or notified body.
Grant of MD5 License: Upon successful audit and satisfaction of all requirements, the license is issued on Form MD5.
Manufacturing License Documents Required
Manufacturers must prepare and submit comprehensive documentation, including:
- Company Constitution/Registration Certificate
- Proof of Ownership/Lease of Manufacturing Premises
- Details and Qualifications of Technical Staff
- Fire NOC and Pollution Control Board NOC
- Device Master File (DMF): Detailed device design and manufacturing process. Our detailed Device Master File guide offers practical insights.
- Plant Master File (PMF): Documentation of manufacturing facility and quality systems. Learn how to create a compliant Plant Master File.
- Essential Principles Checklist Compliance
- Risk Management File aligned with ISO 14971 standards
- Test Reports from CDSCO approved labs
- Labels and Instructions for Use (IFU)
- Quality Management System (QMS) documents, e.g., ISO 13485 certification
Import License Process (MD15) for Trocars
Importers of Class B trocars must apply for an MD15 import license, a process managed by the Central Licensing Authority. The overall timeline is approximately 5 to 6 months.
Key steps include:
Document Preparation: Collect required documents including manufacturing license of the foreign manufacturer, Free Sale Certificate, ISO 13485:2016 certification, CE certificate (if applicable), Device Master File, Plant Master File, wholesale license, and company constitution.
Application Submission: File application on the CDSCO MD Online Portal using Form MD14.
Query Resolution: Address any clarifications sought by the CDSCO.
License Grant: After review, the MD15 license is granted.
Import License Documents Required
To ensure smooth processing, importers should prepare the following documents:
- Manufacturing License of the foreign manufacturer
- Free Sale Certificate issued by the country of origin
- ISO 13485:2016 certification
- CE Certificate or other regulatory approvals
- Device Master File and Plant Master File
- Wholesale Drug License for import
- Company Constitution and address proof
Timeline and Processing Duration
License Type | Approximate Duration | Key Milestones |
---|---|---|
Test License (MD13) | 1.5 - 2 months | Application, Testing, Test License Issuance |
Manufacturing License (MD5) | 3 - 4 months | Audit, Query Resolution, License Grant |
Import License (MD15) | 5 - 6 months | Document Verification, Query Resolution, License Grant |
Government Fees and Costs
For Class B trocars, the fee structure is as follows:
- MD5 Manufacturing License: Rs 5,000 per application + Rs 500 per product
- MD15 Import License: Approx USD 2,000 per site + USD 1,000 per product
Additional costs include:
- Testing fees at CDSCO approved labs
- Audit fees charged by notified bodies
- Consultancy fees if you engage regulatory experts
Common Challenges and Practical Solutions
Challenge 1: Delays in testing and audit scheduling
- Solution: Pre-book testing slots with CDSCO notified labs early and prepare audit documentation well in advance.
Challenge 2: Incomplete or inconsistent documentation
- Solution: Use comprehensive checklists and templates for Device and Plant Master Files; consider leveraging our expert guides for DMF and PMF creation.
Challenge 3: Responding to unexpected queries from CDSCO
- Solution: Maintain open communication with regulatory authorities and prepare detailed, evidence-backed responses promptly.
Challenge 4: Understanding classification and applicable fees
- Solution: Verify device classification through official sources such as the Medical Device Classification guide.
Expert Consultation and Support
Navigating CDSCO licensing for trocars can be complex and time-consuming. Our team has supported over 500 companies through every stage of the process—from initial classification advice to post-approval compliance. We offer:
- Customized gap analysis of your current documentation
- End-to-end application preparation and submission
- Coordination with notified bodies and testing labs
- Training on regulatory requirements and QMS implementation
Getting Started with Your CDSCO License Application for Trocars
- Confirm your device classification as Class B catheters based on CDSCO notifications.
- Register your organization on the CDSCO MD Online Portal to initiate applications.
- Prepare your test license (MD13) application if manufacturing, or gather import documents if importing.
- Engage with CDSCO approved testing laboratories early to schedule product testing.
- Develop or update your Device and Plant Master Files using our comprehensive guides.
- Plan for notified body audit by selecting from the approved notified bodies.
- Submit your MD5 or MD15 license application with complete documentation.
By following these actionable steps and leveraging expert support, manufacturers and importers can significantly reduce approval times and avoid common pitfalls. Contact us today to discuss your specific needs and start your CDSCO licensing journey with confidence.