CDSCO License for Ultrasonic scanner calibration test block.
Medical Device Information
Important Notice for Class A Devices
Class A Non-sterile Non Measuring devices are exempt from MD5 and MD15 licenses. Only CDSCO registration is required as per GSR 777(E).
Intended Use
An ultrasonic scanner calibration test block is a block of material with known properties used to calibrate ultrasonic scanning devices (e.g., the echoencephalograph)

Comprehensive Guide to CDSCO Licensing for Ultrasonic Scanner Calibration Test Blocks (Class A Medical Device)
Introduction: Understanding Ultrasonic Scanner Calibration Test Blocks and Regulatory Significance
Ultrasonic scanner calibration test blocks are specialized devices designed to ensure the accuracy and reliability of ultrasonic scanning equipment, such as echoencephalographs, used in neurological diagnostics. These blocks have precisely known acoustic properties, allowing healthcare providers to calibrate ultrasonic devices effectively. Given their critical role in patient diagnosis and device performance, regulatory oversight by the Central Drugs Standard Control Organization (CDSCO) in India is mandatory for manufacturers and importers.
Navigating the CDSCO licensing process for these Class A medical devices requires a clear understanding of India’s regulatory framework, timelines, costs, and documentation to avoid delays and ensure market entry compliance. With over 25 years of experience and having supported 500+ companies in obtaining CDSCO licenses, we provide detailed, practical insights for your successful application.
CDSCO Regulatory Framework for Ultrasonic Scanner Calibration Test Blocks
Classified as Class A under the CDSCO risk classification, ultrasonic scanner calibration test blocks fall under the “low risk” category. The regulatory process is primarily overseen by the State Licensing Authority, which issues the manufacturing license known as the MD5 license. The regulatory framework requires compliance with the Medical Device Rules, 2017, adherence to quality management systems (ISO 13485:2016), and fulfillment of testing and documentation requirements.
Manufacturers must also follow the notification 29/Misc/03/2020-DC (201) dated 27.09.2021, which specifically addresses classification and regulatory updates relevant to neurological calibration devices.
Risk Classification and License Requirements for Ultrasonic Scanner Calibration Test Blocks
- Risk Class: A (Low risk)
- Regulatory Authority: State Licensing Authority
- Required License: MD5 Manufacturing License (Form MD3)
- Testing License: Initially, a Test License (Form MD13) is mandatory before the manufacturing license application
This classification means the device undergoes a streamlined regulatory process compared to higher-risk devices (Class C/D), but attention to detail in documentation and testing remains crucial.
For more on medical device classification, refer to our detailed Medical Device Classification guide.
Manufacturing License Process (MD5) for Ultrasonic Scanner Calibration Test Blocks
- Apply for Test License (Form MD13): Initiate the process by submitting an application for a test license, allowing you to manufacture the device for testing purposes.
- Product Testing: Submit samples to government-approved testing laboratories to validate device performance. Refer to the list of testing laboratories recognized by CDSCO.
- Documentation Preparation: Compile the Device Master File, Plant Master File, Risk Management File, and other mandatory documents.
- Apply for Manufacturing License (Form MD3): Submit the manufacturing license application via the CDSCO MD Online Portal.
- Audit by Notified Body: Undergo an audit by a notified body listed in the Notified Bodies List to ensure compliance with quality and manufacturing standards.
- Queries Resolution: Respond promptly to any queries raised by the State Licensing Authority or notified body during evaluation.
- License Grant: Upon satisfactory completion of all steps, the authority issues the MD5 license (Form MD5), permitting commercial manufacturing.
For a detailed step-by-step walkthrough, our MD5 License Guide provides valuable insights.
Manufacturing License Documents Required for Ultrasonic Scanner Calibration Test Blocks
Successful MD5 license applications require comprehensive documentation including:
- Company Constitution Documents: Incorporation certificate, partnership deed, or other relevant legal documents.
- Proof of Ownership or Rent Agreement: Valid documents demonstrating ownership or lease of manufacturing premises.
- Technical Staff Details: CVs, qualifications, and experience certificates of qualified technical personnel.
- Fire NOC & Pollution Control NOC: Clearance certificates from appropriate local authorities.
- Device Master File (DMF): Detailed technical dossier covering device design, components, manufacturing process, and compliance. Our Device Master File guide helps you prepare this critical document.
- Plant Master File (PMF): Information on manufacturing facilities, equipment, and quality systems. See our Plant Master File guide for best practices.
- Essential Principles Checklist: Demonstrates compliance with the Medical Device Rules’ essential principles.
- Risk Management File: Documented risk analysis and mitigation per ISO 14971 standards. Learn more about risk management here.
- Test Reports: Laboratory test results validating device safety and performance.
- Labels and Instructions for Use (IFU): Drafts of product labels and user manuals.
- Quality Management System Documents: ISO 13485:2016 certification and related SOPs.
Ensuring completeness and accuracy of these documents significantly reduces processing time and audit queries.
Import License Process (MD15) for Ultrasonic Scanner Calibration Test Blocks
While our focus is primarily on manufacturing licenses for Class A devices, importers intending to bring ultrasonic scanner calibration test blocks into India must apply for an Import License (MD15) through the Central Licensing Authority.
Key steps include:
- Preparing required documentation such as manufacturing license from the country of origin, Free Sale Certificate, ISO 13485:2016 certificates, and CE certificates.
- Applying on the CDSCO MD Online Portal using Form MD14.
- Resolving any queries raised during the evaluation.
- Awaiting license issuance, typically within 5-6 months.
For a comprehensive guide, please consult our Import License Guide.
Import License Documents Required
- Valid Manufacturing License from the country of origin
- Free Sale Certificate
- ISO 13485:2016 Quality Management System Certificate
- CE Certificate or equivalent
- Device Master File
- Plant Master File
- Wholesale license in India
- Company Constitution Documents
Compliance with these requirements ensures smooth clearance of imported products.
Timeline and Processing Duration
Process Step | Duration |
---|---|
Test License (MD13) Application | 1.5 to 2 months |
Product Testing | 3 to 4 weeks |
Document Preparation | 2 to 3 weeks |
Manufacturing License (MD5) Application & Audit | 1.5 to 2 months |
Total Estimated Timeline | Approx. 3 to 4 months |
Planning your project timeline with these estimates helps prevent costly delays and allows for efficient resource allocation.
Government Fees and Costs
- Test License (MD13): Typically included in overall costs; verify with State Authority
- MD5 Manufacturing License Application Fee: Rs 5,000 per application
- Product Fee: Rs 500 per product
- Audit and Testing Fees: Variable, depending on notified body and laboratory charges
Budgeting for these fees upfront is critical. Also, consider ancillary costs such as document preparation, consultant fees, and potential re-testing.
Common Challenges and Practical Solutions
1. Delayed Test Reports: Testing laboratories often have backlogs, leading to delays. To mitigate, pre-book slots at government-approved labs early. Check the list of approved testing laboratories.
2. Incomplete Documentation: Applications rejected or delayed due to missing or inconsistent documents. Use comprehensive checklists and expert reviews before submission.
3. Audit Non-Compliance: Failure in audit due to inadequate QMS or facility gaps. Conduct pre-audit internal reviews and engage notified bodies early.
4. Queries from Authority: Slow response to queries prolongs processing. Assign dedicated regulatory personnel to monitor communications and respond promptly.
5. Regulatory Updates: Changes in guidelines can impact your application. Subscribe to CDSCO notifications and consult experienced regulatory consultants to stay informed.
Expert Consultation and Support
With over 25 years of experience and a track record of assisting 500+ medical device companies, we offer tailored consultation to help you navigate the CDSCO licensing maze. From document preparation, audit readiness, to application submission on the CDSCO MD Online Portal, our experts ensure your ultrasonic scanner calibration test block gains timely market approval.
Our services include:
- Personalized gap analysis for documentation
- Assistance with Device and Plant Master Files
- Coordination with notified bodies and testing labs
- Comprehensive audit preparation
- Post-approval compliance support
Getting Started with Your CDSCO License Application
To initiate your MD5 license application for ultrasonic scanner calibration test blocks, follow these practical next steps:
- Assess Your Device Classification: Confirm Class A status using official CDSCO notifications and resources.
- Prepare Internal Documentation: Gather company constitution, premises ownership proof, and technical staff credentials.
- Engage a Government-Approved Testing Laboratory: Schedule product testing early to avoid bottlenecks.
- Apply for Test License (Form MD13): Submit via the CDSCO MD Online Portal.
- Develop Device and Plant Master Files: Refer to our detailed Device Master File guide and Plant Master File guide for templates and tips.
- Implement Risk Management Practices: Document per ISO standards to ensure compliance.
- Submit Manufacturing License Application (Form MD3): After test license issuance and testing, file your MD5 application.
- Prepare for Audit: Coordinate with notified bodies early and conduct internal pre-audits.
- Respond to Queries Promptly: Assign responsible personnel to handle regulatory communications.
By following these steps and leveraging expert support, manufacturers can confidently navigate India's regulatory landscape and bring their ultrasonic scanner calibration test blocks to market efficiently and compliantly.
For personalized assistance and comprehensive regulatory services, contact us to start your CDSCO licensing journey today.