Logo
Chat on WhatsApp

CDSCO License for Ureteral stent

Medical Device Information

Device Class
Class C

Intended Use

Indicated to relieve obstructions in variety of benign, malignant and post- traumatic condition in the ureter. These conditions include stones and/or stone fragments or other Ureteral obstructions such as those associated with ureteral strictures, malignancy of abdominal organs, retroperitoneal fibrosis or ureteral trauma or in association with the Extracoporeal Shock wave lithotripsy (ESWL). The stent may be placed using endoscopic or percutaneously using standard or radiographic technique.

Manufacturing License
MD9
Import License
MD15
CDSCO License for Ureteral stent

Introduction to Ureteral Stents and CDSCO Licensing Importance

Ureteral stents are critical medical devices designed to relieve obstructions in the ureter caused by various benign, malignant, and post-traumatic conditions. Their usage spans treatments involving stones, strictures, malignancies, and trauma, often deployed via endoscopic or percutaneous methods. Given their invasive nature and direct impact on patient safety, ureteral stents are classified as Class C medical devices under the Indian regulatory framework.

Navigating the Central Drugs Standard Control Organization (CDSCO) licensing process is essential for manufacturers and importers aiming to market ureteral stents in India. Compliance ensures device safety, efficacy, and regulatory approval, ultimately fostering trust among healthcare professionals and patients.

CDSCO Regulatory Framework for Ureteral Stents (Class C Devices)

Ureteral stents fall under the category of Catheters and are classified as Class C devices according to the CDSCO classification system. This classification mandates a stringent regulatory pathway involving the Central Licensing Authority, reflecting the moderate to high risk associated with their use.

India’s regulatory framework for medical devices is governed by the Medical Device Rules (MDR) 2017, which outline specific licensing requirements based on risk classification. For Class C devices, the manufacturing license is granted through an MD9 license, while importers must obtain an MD15 import license.

Risk Classification and License Requirements for Ureteral Stents

  • Device: Ureteral Stent
  • Risk Class: C (Moderate to High Risk)
  • License Type:
    • Manufacturing: MD9 License (Application Form MD7)
    • Import: MD15 License (Application Form MD14)
  • Regulatory Authority: Central Licensing Authority (CDSCO, New Delhi)

Given the classification, manufacturers must engage in a comprehensive testing, documentation, and audit process before license approval.

Manufacturing License Process for Ureteral Stents (MD9 License)

Obtaining an MD9 manufacturing license involves several critical steps:

  1. Test License Acquisition (Form MD13): Before full license application, manufacturers must secure a test license, which authorizes initial manufacturing for testing purposes. This process typically takes 1.5 to 2 months.

  2. Product Testing: Samples of the ureteral stent must be tested at CDSCO-approved laboratories to verify compliance with Indian standards. Refer to the CDSCO Testing Laboratories list for authorized facilities.

  3. Document Preparation: Prepare and compile all required documents including technical files, risk management, and quality system documentation.

  4. Application Submission: Submit the MD9 license application via the CDSCO MD Online Portal using Form MD7.

  5. Inspection and Audit: CDSCO inspectors conduct audits of manufacturing facilities and review documentation to verify compliance.

  6. Query Resolution: Address any queries raised by CDSCO officials during the evaluation.

  7. License Grant: Upon successful compliance, the manufacturing license is granted on Form MD9.

The entire process from test license to final approval generally takes between 4 to 5 months.

Manufacturing License Documents Required for MD9

To streamline your application, ensure the following documentation is complete and accurate:

  • Company Constitution/Registration certificate
  • Proof of ownership or lease agreement of manufacturing premises
  • Details and qualifications of technical and managerial staff
  • Fire No Objection Certificate (NOC)
  • Pollution Control Board Clearance
  • Device Master File (DMF) detailing design, specifications, and manufacturing processes (Device Master File Guide)
  • Plant Master File (PMF) describing manufacturing facility and quality systems (Plant Master File Guide)
  • Essential Principles Compliance Checklist
  • Risk Management File according to ISO 14971 standards (Risk Management)
  • Test Reports from government-approved laboratories
  • Product labels and Instructions for Use (IFU)
  • Quality Management System (QMS) documents, typically ISO 13485:2016 certification

Import License Process for Ureteral Stents (MD15 License)

Importers intending to bring ureteral stents into India must apply for an MD15 import license from the CDSCO Central Licensing Authority. The process includes:

  1. Document Preparation: Gather all necessary documents including manufacturing licenses from the country of origin, quality certifications, and product technical files.

  2. Application Submission: File the application using Form MD14 on the CDSCO MD Online Portal.

  3. Review and Query Resolution: The CDSCO reviews the application and may request clarifications or additional documents.

  4. License Grant: After satisfactory evaluation, the import license is issued on Form MD15.

The typical processing time for an MD15 import license is approximately 5 to 6 months.

Import License Documents Required for MD15

  • Valid manufacturing license of the product in the country of origin
  • Free Sale Certificate or Certificate of Export from the country of origin
  • ISO 13485:2016 certification
  • CE Certificate or equivalent regulatory approval
  • Device and Plant Master Files
  • Wholesale Drug License (if applicable)
  • Company Constitution/Registration
  • Label and IFU copies

Timeline and Processing Duration

License TypeSteps IncludedDuration
MD9 ManufacturingTest License, Product Testing, Audit, License4 to 5 months
MD15 ImportDocument Review, Query Resolution, License5 to 6 months

Manufacturers should plan their market entry strategies accordingly, allowing time for potential queries and re-submissions.

Government Fees and Costs

  • MD9 Manufacturing License:

    • Application fee: Rs. 50,000
    • Per product fee: Rs. 1,000
  • MD15 Import License:

    • Class C & D devices: USD 3,000 per site
    • USD 1,500 per product

These fees are payable online via the CDSCO portal during application submission.

Common Challenges and Solutions

  • Delayed Testing: Testing at government-approved labs can be a bottleneck. Early sample submission and coordination with labs can mitigate delays.

  • Incomplete Documentation: Many applicants face rejection due to missing or inconsistent documents. Utilize comprehensive checklists and consult expert guides.

  • Audit Readiness: Preparing for CDSCO audits requires robust quality systems and facility compliance. Conduct internal audits and gap analyses beforehand.

  • Query Management: Prompt and detailed responses to CDSCO queries help avoid prolonged approval times.

Our extensive experience with over 500 successful client projects has enabled us to develop streamlined strategies to overcome these challenges effectively.

Expert Consultation and Support

Engaging with seasoned regulatory consultants can significantly ease the licensing journey. We provide:

  • End-to-end application handling
  • Document preparation and review
  • Liaison with CDSCO officials
  • Audit preparedness training
  • Post-license compliance support

Our detailed MD9 License Guide and Import License Guide offer valuable insights tailored for Class C device manufacturers and importers.

Getting Started with Your CDSCO License Application for Ureteral Stents

To initiate your CDSCO licensing process for ureteral stents:

  1. Assess Your Device Classification: Confirm your device is Class C as per the Medical Device Classification guidelines.

  2. Prepare Your Quality System: Ensure your QMS aligns with ISO 13485:2016 standards.

  3. Compile Essential Documents: Begin gathering corporate, technical, and quality documentation.

  4. Engage a Notified Body: For MD9 license, select a notified body from the CDSCO Notified Bodies List to plan your audit.

  5. Submit Test License Application: Apply for the initial test license (Form MD13) via the CDSCO MD Online Portal.

  6. Plan Product Testing: Coordinate with approved testing laboratories early.

  7. Prepare for Audit: Conduct internal readiness assessments.

By following these practical steps and leveraging expert support, your journey towards obtaining CDSCO approval for ureteral stents can be efficient and successful.

For detailed assistance, contact our regulatory consultancy team with over 25 years of proven expertise in Indian medical device compliance.

Get Expert Help

Free consultation for your medical device license

24/7 Support Available

Why Choose Us

500+ Licenses Obtained
100% Success Rate
15+ Years Experience
24/7 Support Available

About the Author

avatar
Tails Azimuth
@Twitter