CDSCO License for Non-rechargeable public semi- automated external defibrillator electrode, paediatric
Medical Device Information
Intended Use
An electrical conductor, with integral batteries and regulated by a dedicated external pulse generator (EPG), designed to create an electrical shock(s) and defibrillate the heart (restore normal rhythm) to treat ventricular fibrillation or pulseless ventricular tachycardia in a pre-pubescent patient. It is a cartridge-type electrode, in pairs, with non-rechargeable batteries that provide the energy to produce the electrical shock(s) after its adhesive pads are placed on the skin of the patient. This is a single-use device that is replaced after a patient application or after elapse of its expiry date.

Comprehensive CDSCO Licensing Guide for Non-Rechargeable Paediatric Semi-Automated External Defibrillator Electrodes
Introduction: Understanding Your Device and Regulatory Landscape
The non-rechargeable public semi-automated external defibrillator electrode for paediatrics is a critical medical device designed specifically to deliver lifesaving electrical shocks to pre-pubescent patients experiencing ventricular fibrillation or pulseless ventricular tachycardia. This single-use, cartridge-type electrode with integral batteries works in tandem with an external pulse generator, restoring normal heart rhythm efficiently and safely.
Given its application in sensitive pediatric and neonatology care, regulatory compliance in India is paramount to ensure safety, efficacy, and quality. Navigating the Central Drugs Standard Control Organisation (CDSCO) licensing process is crucial for manufacturers and importers aiming to legally market this device in India.
CDSCO Regulatory Framework for Semi-Automated External Defibrillator Electrodes
As per the CDSCO regulations, this device falls under the purview of medical devices governed by the Medical Device Rules, 2017, which align closely with global best practices. The device is categorized under Class B – Moderate Risk – mandating a stringent but manageable regulatory pathway.
Risk Classification and License Requirements for Class B Devices
Class B devices like the paediatric semi-automated external defibrillator electrode require obtaining an MD5 manufacturing license. This license is issued by the State Licensing Authority and involves several stages including test licensing, product testing, document preparation, and audits.
For importers, an MD15 import license from the Central Licensing Authority is necessary, but since this content focuses on manufacturing, we emphasize the MD5 pathway here.
Learn more about medical device classification to confirm your device’s categorization.
Manufacturing License Process for MD5 (Class B Devices)
The MD5 licensing process for your device involves the following key steps:
- Test License Application (Form MD13): Before full manufacturing license, a test license is mandatory. This permits manufacturing for testing and validation purposes.
- Product Testing: The device must be tested at CDSCO-approved testing laboratories to verify compliance with essential principles and performance standards. Refer to the list of testing laboratories for approved centers.
- Documentation Preparation: Compile comprehensive technical documentation including Device Master File, Plant Master File, Essential Principles Checklist, Risk Management File, and Quality Management System (QMS) documents.
- Filing the Application (Form MD3): Submit the manufacturing license application through the CDSCO MD Online Portal.
- Audit by Notified Body: An external audit by a notified body is mandatory. Check the list of notified bodies approved for MD5 audits.
- Resolution of Queries: Address any observations or queries from CDSCO and the notified body promptly.
- Grant of MD5 License: Upon satisfactory compliance, the license is granted on Form MD5.
Manufacturing License Documents Required
For your paediatric semi-automated external defibrillator electrode (Class B), the following documents are essential:
- Company Constitution (e.g., MOA, AOA)
- Proof of ownership or legal tenancy of manufacturing premises
- Technical staff qualifications and experience certificates
- Fire No Objection Certificate (NOC)
- Pollution Control Board NOC
- Device Master File (DMF): Detailed device design, materials, specifications. Our Device Master File guide can assist in preparation.
- Plant Master File (PMF): Manufacturing process details, infrastructure, and equipment. Refer to our Plant Master File guide.
- Essential Principles Checklist confirming compliance with Indian regulations
- Risk Management File documenting hazard analysis and mitigation strategies. Explore medical device risk management for best practices.
- Test Reports from CDSCO-approved labs validating device safety and performance
- Labels and Instructions for Use (IFU) complying with regulatory standards
- Quality Management System documents, preferably ISO 13485:2016 certified
Import License Process (MD15) – Brief Overview
If you plan to import these electrodes into India, you must apply for the MD15 import license through the Central Licensing Authority. This process generally takes 5-6 months and requires documentation such as manufacturing license, Free Sale Certificate, ISO 13485:2016, CE Certificate, Device and Plant Master Files, wholesale license, and company constitution. Application is done via the CDSCO MD Online Portal.
For detailed guidance, consult our Import License Guide.
Timeline and Processing Duration
The typical timeline for obtaining an MD5 manufacturing license for a Class B device like yours is approximately 3-4 months, broken down as follows:
- Test License (Form MD13): 1.5 to 2 months
- Product Testing at CDSCO-approved labs: 2-4 weeks depending on lab workload
- Document preparation and submission: 2-3 weeks
- Audit by Notified Body: Scheduled within 3-4 weeks post application
- Resolution of queries and final approval: 3-4 weeks
Being proactive in documentation and audit readiness can help avoid delays.
Government Fees and Costs
The fee structure for your MD5 license is as follows:
- Application fee: Rs 5,000 per manufacturing site
- Product fee: Rs 500 per product (for your device, each electrode pair counts as one product)
Additional costs to consider include testing laboratory fees (varies by test scope), notified body audit fees, and consultancy if you engage expert support.
Common Challenges and Practical Solutions
Challenge 1: Delays in Test License and Product Testing
- Solution: Initiate test license application early and schedule product testing at multiple approved labs to avoid bottlenecks.
Challenge 2: Incomplete Documentation Leading to Query Backlogs
- Solution: Utilize checklists and expert review of your Device and Plant Master Files, risk management, and essential principles documentation.
Challenge 3: Audit Non-Compliance
- Solution: Conduct internal mock audits and ensure all manufacturing and QMS processes are in line with CDSCO requirements.
Challenge 4: Labeling and IFU Non-Adherence
- Solution: Follow CDSCO labeling guidelines strictly and validate IFU clarity with clinical experts.
Expert Consultation and Support
With over 25 years of experience and having successfully supported 500+ companies in CDSCO licensing, we provide end-to-end consultancy tailored for your paediatric defibrillator electrode device. From preparing your Device Master File to coordinating audits and responding to CDSCO queries, our expert team ensures a smooth, compliant journey.
Getting Started with Your CDSCO License Application
- Initiate a Gap Analysis: Assess your current manufacturing setup against CDSCO requirements.
- Prepare Test License Application (MD13): Compile required documents and submit via the CDSCO MD Online Portal.
- Engage a CDSCO-Approved Testing Laboratory: Schedule your product testing early.
- Develop Comprehensive Technical Documentation: Use our Device Master File guide and Plant Master File guide for reference.
- Select a Notified Body for Audit: Refer to the list of notified bodies and schedule your audit.
- Submit Manufacturing License Application (MD3): Ensure all documents are complete and accurate.
- Prepare for Query Resolution: Designate a responsible team to respond swiftly.
Embarking on your CDSCO licensing journey with a clear roadmap and expert support can significantly reduce time to market and regulatory risks. Contact us to leverage our extensive expertise and streamline your compliance process.
Useful Resources:
- CDSCO MD Online Portal
- List of Notified Bodies
- List of Testing Laboratories
- Device Master File Guide
- Plant Master File Guide
For personalized assistance, reach out to our regulatory consultants today.